Skip to content

Main content

QC Sample Dry Mass Correction

Apply an explicitly supplied wet-basis moisture fraction to sample mass without measuring moisture content.

Loading tool…

Description

Calculate dry sample mass from a wet-basis moisture fraction.

Quality-control results depend on measurement basis, calibration reference, rounding, limit inclusion and decision rules. A raw result can lie on a different side of a boundary from its reported value. Guard bands and relative differences must retain their exact definitions; a local comparison does not select a valid specification or establish conformance.

Calculate dry sample mass from a wet-basis moisture fraction.

When to use this tool

Use QC Sample Dry Mass Correction when you already have wetSampleMass, moistureFraction and need to calculate dry sample mass from a wet-basis moisture fraction.

How to use the tool and how it works

  1. Enter wetSampleMass, moistureFraction. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read drySampleMass. Use the output convention below.

Require wetSampleMass>=0 and moistureFraction in [0,1]; return wet mass*(1-fraction).1

Input fieldMeaning and unitsAccepted input
wetSampleMassWet Sample MassRequired. Finite number; minimum 0.
moistureFractionWater mass/wet sample mass as a decimal fraction; includes one.Required. Finite number; minimum 0; maximum 1.
Output fieldInterpretationReturned shape
drySampleMassDry Sample MassRequired. Finite number.
json
{
  "input": {
    "wetSampleMass": 100,
    "moistureFraction": 0.2
  },
  "output": {
    "drySampleMass": 80
  }
}

Limitations and assumptions

  • The fraction means water mass/wet mass, not dry-basis water ratio; no drying procedure or analytical correction is validated.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Apply the documented measurement method, calibration records and complete decision rule when judging a result. Keep raw values, reported values, uncertainty and endpoint inclusion visible; a supplied guard band or replicate term does not select that rule.

References

  1. Calculation and input contract: quality-control/qc-sample-dry-mass-correction — tool.io

Similar or alternative tools