Skip to content

Main content

Pharmacognosy Swelling Index Volume Term Tool

Report explicitly supplied volume expansion with a separate blank correction.

Loading tool…

Description

Report explicitly supplied volume expansion with a separate blank correction.

Botanical laboratory records distinguish wet mass, dry matter, carriers, extract mass, and assay response. A fraction or reference comparison depends on the chosen material basis and supplied analytical method. Voucher and monograph metadata help identify records but do not themselves authenticate a specimen or establish product quality.

Report explicitly supplied volume expansion with a separate blank correction.

When to use this tool

Use Pharmacognosy Swelling Index Volume Term when you need this mass-basis, assay-response, extraction, or source-record calculation for supplied laboratory data.

How to use the tool and how it works

  1. Enter initialVolume, finalVolume, dryMass, blankExpansion. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read netExpansion, expansionPerMass, finalVolumePerMass. Use the output convention below.

For positive dryMass and nonnegative initialVolume, finalVolume, and blankExpansion return netExpansion=finalVolume-initialVolume-blankExpansion, expansionPerMass=netExpansion/dryMass, and finalVolumePerMass=finalVolume/dryMass.1

Input fieldMeaning and unitsAccepted input
initialVolumeInitial VolumeRequired. Finite number; minimum 0.
finalVolumeFinal VolumeRequired. Finite number; minimum 0.
dryMassDry MassRequired. Finite number; strictly above 0.
blankExpansionBlank ExpansionRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
netExpansionNet ExpansionRequired. Finite number.
expansionPerMassBlank-corrected volume expansion per dry-mass unit; can be negative.Required. Finite number.
finalVolumePerMassFinal Volume Per MassRequired. Finite number.
json
{
  "input": {
    "initialVolume": 2,
    "finalVolume": 10,
    "dryMass": 4,
    "blankExpansion": 0.5
  },
  "output": {
    "netExpansion": 7.5,
    "expansionPerMass": 1.875,
    "finalVolumePerMass": 2.5
  }
}

Limitations and assumptions

  • Volumes need one unit and the two per-mass outputs use the dryMass unit. Negative net expansion is allowed; the tool does not establish a compendial swelling-test method or product compliance.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.

Alternative or Complementary methods

Use the appropriate authenticated reference material, analytical protocol, and source records for a full laboratory assessment. Verify moisture basis, response factors, and extract/carrier definitions before comparing results.

References

  1. Calculation and input contract: pharmacognosy/pharmacognosy-swelling-index-volume-term — tool.io

Similar or alternative tools

  • Essential Oil Reference Volume Factor

    Convert supplied mass/density and explicit volume bases without recommending essential-oil use.

  • Pharmacognosy Ash Value Tare Factor

    For positive sampleMass, nonnegative crucibleMass, crucibleAshMass>=crucibleMass, and moistureFraction in [0,1), return ashMass=crucibleAshMass-crucibleMass, asReceivedFraction=ashMass/sampleMass, and dryFraction=ashMass/(sampleMass*(1-moistureFraction)).