Description

For nonnegative area and positive referenceArea, referenceConcentration, responseFactor, and sampleDilution return areaRatio=area/referenceArea and correctedConcentration=area*referenceConcentration*sampleDilution/(referenceArea*responseFactor).

Botanical laboratory records distinguish wet mass, dry matter, carriers, extract mass, and assay response. A fraction or reference comparison depends on the chosen material basis and supplied analytical method. Voucher and monograph metadata help identify records but do not themselves authenticate a specimen or establish product quality.

For nonnegative area and positive referenceArea, referenceConcentration, responseFactor, and sampleDilution return areaRatio=area/referenceArea and correctedConcentration=area*referenceConcentration*sampleDilution/(referenceArea*responseFactor).

When to use this tool

Use Pharmacognosy HPLC Onepeak Reference Ratio when you need this mass-basis, assay-response, extraction, or source-record calculation for supplied laboratory data.

How to use the tool and how it works

  1. Enter area, referenceArea, referenceConcentration, responseFactor, sampleDilution. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read areaRatio, correctedConcentration. Use the output convention below.

For nonnegative area and positive referenceArea, referenceConcentration, responseFactor, and sampleDilution return areaRatio=area/referenceArea and correctedConcentration=area*referenceConcentration*sampleDilution/(referenceArea*responseFactor).1

Input fieldMeaning and unitsAccepted input
areaArea in a unit compatible with the other physical inputs.Required. Finite number; minimum 0.
referenceAreaReference AreaRequired. Finite number; strictly above 0.
referenceConcentrationReference ConcentrationRequired. Finite number; strictly above 0.
responseFactorPositive dimensionless relative response factor used as a divisor.Required. Finite number; strictly above 0.
sampleDilutionSample DilutionRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
areaRatioArea RatioRequired. Finite number.
correctedConcentrationCorrected ConcentrationRequired. Finite number.
json
{
  "input": {
    "area": 120,
    "referenceArea": 100,
    "referenceConcentration": 2,
    "responseFactor": 1.2,
    "sampleDilution": 5
  },
  "output": {
    "areaRatio": 1.2,
    "correctedConcentration": 10
  }
}

Limitations and assumptions

  • Peak areas need a comparable detector scale and responseFactor is a supplied dimensionless relative response. One-point scaling does not validate peak identity, calibration linearity, extraction recovery, or medicinal safety.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.