Description
Signed field-blank correction with supplied sample volume and recovery.
Occupational exposure calculations combine measured quantities, duration, reference conditions, weighting, and sampling support. Linear concentrations, squared acceleration, and logarithmic sound levels require different arithmetic. A supplied reference or limit is not automatically the applicable standard, and a local calculation is separate from a full exposure and safety assessment.
Signed field-blank correction with supplied sample volume and recovery.
When to use this tool
Use Workplace Air Blank Mass Correction when you need this particular sampling, duration, reference-unit, physical-exposure, or reporting-base term.
How to use the tool and how it works
- Enter preMass, postMass, blankChange, sampledVolume, recovery. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read netMass, recoveredMass, concentration. Use the output convention below.
For positive sampledVolume and recovery in (0,1] return netMass=postMass-preMass-blankChange, recoveredMass=netMass/recovery, and concentration=netMass/(sampledVolume*recovery).1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| preMass | Pre Mass | Required. Finite number. |
| postMass | Post Mass | Required. Finite number. |
| blankChange | Blank Change | Required. Finite number. |
| sampledVolume | Sampled Volume | Required. Finite number; strictly above 0. |
| recovery | Supplied recovery fraction in (0,1]. | Required. Finite number; maximum 1; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| netMass | Net Mass | Required. Finite number. |
| recoveredMass | Recovered Mass | Required. Finite number. |
| concentration | Blank/recovery-corrected mass per supplied sampled-volume unit. | Required. Finite number. |
{
"input": {
"preMass": 10,
"postMass": 12,
"blankChange": 0.2,
"sampledVolume": 3,
"recovery": 0.9
},
"output": {
"netMass": 1.8,
"recoveredMass": 2,
"concentration": 0.6666666666666666
}
} Limitations and assumptions
- Mass terms need one unit and sampledVolume determines the concentration denominator. Negative blank-corrected masses are retained; recovery, sampling efficiency, analytical validity, exposure limits, and workplace safety are not verified.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use a complete hazard-specific assessment with calibrated measurements and the appropriate exposure model. Verify reference conditions, sampling coverage, weighting, denominator, and the applicable professional or regulatory method.
References
Similar or alternative tools
- Sampler Flow Temperature Basis Flag
Ideal dry-gas flow conversion with supplied absolute states; does not infer sampling compliance.
- Dust Sampler Flow Time Volume Term
Trapezoidal sampler flow integration with an explicit volume correction.