Sampler Flow Temperature Basis Flag Tool

Ideal dry-gas flow conversion with supplied absolute states; does not infer sampling compliance.

Loading tool…

Description

Ideal dry-gas flow conversion with supplied absolute states; does not infer sampling compliance.

Occupational exposure calculations combine measured quantities, duration, reference conditions, weighting, and sampling support. Linear concentrations, squared acceleration, and logarithmic sound levels require different arithmetic. A supplied reference or limit is not automatically the applicable standard, and a local calculation is separate from a full exposure and safety assessment.

Ideal dry-gas flow conversion with supplied absolute states; does not infer sampling compliance.

When to use this tool

Use Sampler Flow Temperature Basis Flag when you need this particular sampling, duration, reference-unit, physical-exposure, or reporting-base term.

How to use the tool and how it works

  1. Enter measuredFlow, measuredKelvin, referenceKelvin, measuredPressure, referencePressure, useReference. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read reportedFlow. Use the output convention below.

For nonnegative measuredFlow and positive measuredKelvin, referenceKelvin, measuredPressure, and referencePressure return reportedFlow=measuredFlow*(measuredPressure/referencePressure)*(referenceKelvin/measuredKelvin) if useReference, otherwise measuredFlow.1

Input fieldMeaning and unitsAccepted input
measuredFlowMeasured FlowRequired. Finite number; minimum 0.
measuredKelvinPositive absolute sampling temperature in kelvin.Required. Finite number; strictly above 0.
referenceKelvinPositive absolute reference temperature in kelvin.Required. Finite number; strictly above 0.
measuredPressureMeasured PressureRequired. Finite number; strictly above 0.
referencePressureReference PressureRequired. Finite number; strictly above 0.
useReferenceUse ReferenceRequired. Boolean.
Output fieldInterpretationReturned shape
reportedFlowReported FlowRequired. Finite number.
json
{
  "input": {
    "measuredFlow": 2,
    "measuredKelvin": 300,
    "referenceKelvin": 300,
    "measuredPressure": 100,
    "referencePressure": 200,
    "useReference": true
  },
  "output": {
    "reportedFlow": 1
  }
}

Limitations and assumptions

  • Temperature uses absolute kelvin and pressures share one absolute-pressure unit. This ideal-gas volume-rate conversion omits humidity, nonideal gas effects, sampler behavior, calibration, and validity of an exposure measurement.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use a complete hazard-specific assessment with calibrated measurements and the appropriate exposure model. Verify reference conditions, sampling coverage, weighting, denominator, and the applicable professional or regulatory method.

References

  1. Calculation and input contract: occupational-health/sampler-flow-temperature-basis-flag — tool.io

Similar or alternative tools