Embedded-Service Class Check

Estimate enclosure-accessible power and compare it with a caller-supplied class limit.

Description

Enclosure attenuation estimates accessible optical power from an embedded source.

Enclosure attenuation estimates accessible optical power from an embedded source. A caller limit determines the comparison flag.1

Estimate enclosure-accessible power and compare it with a caller-supplied class limit.

When to use Embedded-Service Class Check

Use this tool to estimate enclosure-accessible power and compare it with a caller-supplied class limit.

Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.

How to use Embedded-Service Class Check and understand its results

  1. Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.
  2. Enter embeddedPowerWatts, enclosureAttenuationDb, accessiblePowerLimitWatts using the field table and calculation rules, then run the tool.
  3. Read accessiblePowerWatts, limitMarginWatts, withinAccessibleLimit. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
embeddedPowerWattsEmbedded laser power (W)number; minimum: 0Required
enclosureAttenuationDbEnclosure attenuation (dB)number; minimum: 0Required
accessiblePowerLimitWattsCaller accessible-power limit (W)number; minimum: 0Required

Enter nonnegative embedded watts, attenuation dB and accessible-power limit. Return power, signed margin and inclusive gate.

accessible=embedded×10^(−attenuationDb/10); margin=limit−accessible

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
accessiblePowerWattsEstimated accessible power (W)number; minimum: 0
limitMarginWattsAccessible-power margin (W)number
withinAccessibleLimitWithin supplied accessible limitboolean
json
{
  "input": {
    "embeddedPowerWatts": 1,
    "enclosureAttenuationDb": 20,
    "accessiblePowerLimitWatts": 0.02
  },
  "output": {
    "accessiblePowerWatts": 0.01,
    "limitMarginWatts": 0.01,
    "withinAccessibleLimit": true
  }
}

Limitations and assumptions

No laser class is assigned. Apertures, service access, interlocks, exposure duration and applicable class limits are not evaluated.

Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.

Alternative or Complementary methods

Use Laser Label Coverage: Compare required laser labels with labels documented at the installation. For a complementary task, use Laser Safety Audit: Compare required laser-safety controls with documented controls.

References

  1. Embedded-Service Class Check — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies