Skip to content

Main content

Granule Sieve Edge Policy Tool

Apply supplied sieve-bin endpoint conventions without selecting a manufacturing specification.

Loading tool…

Description

Require lower < upper and select zero-based positions whose sizes satisfy the chosen inclusive or strict bounds at each end.

Powder density and sieve calculations depend on preparation, tapping, size boundaries, and reporting direction. Computing an index does not choose a validated procedure or acceptance category.

Require lower < upper and select zero-based positions whose sizes satisfy the chosen inclusive or strict bounds at each end.

When to use this tool

Use Granule Sieve Edge Policy when you need a supplied powder-density or sieve-data crosswalk.

How to use the tool and how it works

  1. Enter sizes, lower, upper, lowerClosed, upperClosed. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read selectedPositions. Use the output convention below.

Require lower < upper and select zero-based positions whose sizes satisfy the chosen inclusive or strict bounds at each end.1

Input fieldMeaning and unitsAccepted input
sizesSizesRequired. Array of finite number; maximum items 256.
lowerLowerRequired. Finite number.
upperUpperRequired. Finite number.
lowerClosedLower ClosedRequired. Boolean.
upperClosedUpper ClosedRequired. Boolean.
Output fieldInterpretationReturned shape
selectedPositionsSelected PositionsRequired. Array of safe integer; maximum items 256.
json
{
  "input": {
    "sizes": [
      1,
      2,
      3
    ],
    "lower": 1,
    "upper": 3,
    "lowerClosed": true,
    "upperClosed": false
  },
  "output": {
    "selectedPositions": [
      0,
      1
    ]
  }
}

Limitations and assumptions

  • Size units must match the bounds; measurements and sieve-retention conventions are supplied, not a full particle-size analysis.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Follow the applicable validated test method and interpret results against approved material-specific criteria.

References

  1. Calculation and input contract: industrial-pharmacy/granule-sieve-edge-policy — tool.io

Similar or alternative tools