Skip to content

Main content

Reservoir Level Area Storage Term Tool

Integrate a locally linear area-elevation model from an explicit storage anchor; validity outside the calibrated interval is external.

Loading tool…

Description

Use currentLevel-referenceLevel as height change.

Ideal water-storage and channel geometry uses dimensions, areas, and displacement fractions. Coherent length units determine areas and volumes; actual irregular geometry and hydraulic behavior require additional information.

Use currentLevel-referenceLevel as height change.

When to use this tool

Use Reservoir Level Area Storage Term when you need one explicit geometric component of a tank, bed, conduit, or channel.

How to use the tool and how it works

  1. Enter referenceStorage, referenceLevel, currentLevel, referenceArea, areaSlope. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read currentArea, storage. Use the output convention below.

Use currentLevel-referenceLevel as height change. Return referenceArea+areaSlope × height change and integrate that linear area relation from referenceStorage for storage.1

Input fieldMeaning and unitsAccepted input
referenceStorageReference StorageRequired. Finite number; minimum 0.
referenceLevelReference LevelRequired. Finite number.
currentLevelCurrent LevelRequired. Finite number.
referenceAreaPositive area on the same measurement basis as the sampled area.Required. Finite number; minimum 0.
areaSlopeArea SlopeRequired. Finite number.
Output fieldInterpretationReturned shape
currentAreaCurrent AreaRequired. Finite number.
storageStorageRequired. Finite number.
json
{
  "input": {
    "referenceStorage": 1000,
    "referenceLevel": 10,
    "currentLevel": 12,
    "referenceArea": 100,
    "areaSlope": 20
  },
  "output": {
    "currentArea": 140,
    "storage": 1240
  }
}

Limitations and assumptions

  • Areas at both supplied levels must be nonnegative; areaSlope is area per height and storage can still be negative. This local model does not validate a reservoir curve or extrapolation range.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Check the full surveyed geometry and the physical model before interpreting storage, capacity, or safe operation.