Source Water EC Threshold Lookup

Audit actual source-water EC evidence against independently supplied crop-stage maximum, preserving unknowns; no salinity-ion inference, temperature correction or universal crop threshold.

Description

Source-water EC screening needs a verified crop-stage ceiling and known measurements.

Source-water EC screening needs a verified crop-stage ceiling and known measurements. Missing EC observations are not passing values.1

Enter aligned nonempty unique stage IDs/nonnegative limits, exact query and aligned nonempty nonnegative observations/binary evidence. Return strict-above and unknown indices plus chosen mS/cm ceiling.

When to use Source Water EC Threshold Lookup

Use Source Water EC Threshold Lookup when you need to evaluate the supplied records under the calculation and evidence rules below. No universal crop threshold, temperature compensation or ionic-composition inference is supplied.

Prepare measured container, labor, environmental or inventory records and independently verified stage limits requested. Keep units, temperature conditions and dates consistent.

How to use Source Water EC Threshold Lookup and understand its results

  1. Prepare measured container, labor, environmental or inventory records and independently verified stage limits requested. Keep units, temperature conditions and dates consistent.
  2. Enter callerCropStageIds, callerSourceEcMaximumMsCm, queryCropStageId, observedSourceEcMsCm, measurementEvidenceFlags using the field table and calculation rules, then run the tool.
  3. Read sourceSamplesAboveCallerEcIndices, sourceSamplesWithoutEcEvidence, callerSourceEcMaximumMsCm. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
callerCropStageIdsCaller crop stage idslist of stringRequired
callerSourceEcMaximumMsCmCaller source ec maximum ms cmlist of numberRequired
queryCropStageIdQuery crop stage idstringRequired
observedSourceEcMsCmObserved source ec ms cmlist of numberRequired
measurementEvidenceFlagsMeasurement evidence flagslist of numberRequired

Enter aligned nonempty unique stage IDs/nonnegative limits, exact query and aligned nonempty nonnegative observations/binary evidence. Return strict-above and unknown indices plus chosen mS/cm ceiling.

above=known AND observedEC>selectedCeiling

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
sourceSamplesAboveCallerEcIndicesSource samples above caller ec indiceslist of number
sourceSamplesWithoutEcEvidenceSource samples without ec evidencelist of number
callerSourceEcMaximumMsCmCaller source ec maximum ms cmnumber
json
{
  "input": {
    "callerCropStageIds": [
      "a",
      "b"
    ],
    "callerSourceEcMaximumMsCm": [
      0.5,
      1
    ],
    "queryCropStageId": "a",
    "observedSourceEcMsCm": [
      0.4,
      0.8
    ],
    "measurementEvidenceFlags": [
      1,
      0
    ]
  },
  "output": {
    "sourceSamplesAboveCallerEcIndices": [],
    "sourceSamplesWithoutEcEvidence": [
      1
    ],
    "callerSourceEcMaximumMsCm": 0.5
  }
}

Limitations and assumptions

No universal crop threshold, temperature compensation or ionic-composition inference is supplied.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Extremely large text inputs are rejected. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Seedling EC Target Lookup: Final nutrient-solution EC differs from source-water EC. A verified seedling-stage band defines this local check. For a complementary task, use Conductivity Salinity Freshwater Approximation Converter: Freshwater conductivity-to-salinity conversion needs local calibration and a stated temperature normalization. Ionic composition affects the relation.

References

  1. Source Water EC Threshold Lookup — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies