Source Water EC Threshold Lookup
Audit actual source-water EC evidence against independently supplied crop-stage maximum, preserving unknowns; no salinity-ion inference, temperature correction or universal crop threshold.
Description
Source-water EC screening needs a verified crop-stage ceiling and known measurements.
Source-water EC screening needs a verified crop-stage ceiling and known measurements. Missing EC observations are not passing values.1
Enter aligned nonempty unique stage IDs/nonnegative limits, exact query and aligned nonempty nonnegative observations/binary evidence. Return strict-above and unknown indices plus chosen mS/cm ceiling.
When to use Source Water EC Threshold Lookup
Use Source Water EC Threshold Lookup when you need to evaluate the supplied records under the calculation and evidence rules below. No universal crop threshold, temperature compensation or ionic-composition inference is supplied.
Prepare measured container, labor, environmental or inventory records and independently verified stage limits requested. Keep units, temperature conditions and dates consistent.
How to use Source Water EC Threshold Lookup and understand its results
- Prepare measured container, labor, environmental or inventory records and independently verified stage limits requested. Keep units, temperature conditions and dates consistent.
- Enter callerCropStageIds, callerSourceEcMaximumMsCm, queryCropStageId, observedSourceEcMsCm, measurementEvidenceFlags using the field table and calculation rules, then run the tool.
- Read sourceSamplesAboveCallerEcIndices, sourceSamplesWithoutEcEvidence, callerSourceEcMaximumMsCm. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| callerCropStageIds | Caller crop stage ids | list of string | Required |
| callerSourceEcMaximumMsCm | Caller source ec maximum ms cm | list of number | Required |
| queryCropStageId | Query crop stage id | string | Required |
| observedSourceEcMsCm | Observed source ec ms cm | list of number | Required |
| measurementEvidenceFlags | Measurement evidence flags | list of number | Required |
Enter aligned nonempty unique stage IDs/nonnegative limits, exact query and aligned nonempty nonnegative observations/binary evidence. Return strict-above and unknown indices plus chosen mS/cm ceiling.
above=known AND observedEC>selectedCeiling Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| sourceSamplesAboveCallerEcIndices | Source samples above caller ec indices | list of number |
| sourceSamplesWithoutEcEvidence | Source samples without ec evidence | list of number |
| callerSourceEcMaximumMsCm | Caller source ec maximum ms cm | number |
{
"input": {
"callerCropStageIds": [
"a",
"b"
],
"callerSourceEcMaximumMsCm": [
0.5,
1
],
"queryCropStageId": "a",
"observedSourceEcMsCm": [
0.4,
0.8
],
"measurementEvidenceFlags": [
1,
0
]
},
"output": {
"sourceSamplesAboveCallerEcIndices": [],
"sourceSamplesWithoutEcEvidence": [
1
],
"callerSourceEcMaximumMsCm": 0.5
}
} Limitations and assumptions
No universal crop threshold, temperature compensation or ionic-composition inference is supplied.
Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Extremely large text inputs are rejected. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use Seedling EC Target Lookup: Final nutrient-solution EC differs from source-water EC. A verified seedling-stage band defines this local check. For a complementary task, use Conductivity Salinity Freshwater Approximation Converter: Freshwater conductivity-to-salinity conversion needs local calibration and a stated temperature normalization. Ionic composition affects the relation.
References
-
Source Water EC Threshold Lookup — tool.io
Similar or alternative tools
- Seedling EC Target Lookup
Final nutrient-solution EC differs from source-water EC. A verified seedling-stage band defines this local check.
- Conductivity Salinity Freshwater Approximation Converter
Freshwater conductivity-to-salinity conversion needs local calibration and a stated temperature normalization. Ionic composition affects the relation.