Conductivity Salinity Freshwater Approximation Converter

Use explicit local freshwater conductivity/salinity calibration after caller linear temperature normalization; not universal seawater practical salinity, ionic composition inference or chemistry certification.

Description

Freshwater conductivity-to-salinity conversion needs local calibration and a stated temperature normalization.

Freshwater conductivity-to-salinity conversion needs local calibration and a stated temperature normalization. Ionic composition affects the relation.1

Enter nonnegative EC/temperature coefficient, finite temperatures and positive slope/calibration maximum. Require positive factor and normalized EC≤maximum; return reference EC and g/kg.

When to use Conductivity Salinity Freshwater Approximation Converter

Use Conductivity Salinity Freshwater Approximation Converter when you need to evaluate the supplied records under the calculation and evidence rules below. No universal seawater practical-salinity, ion-composition or chemistry certification is supplied.

Prepare the observed lake or sample measurements and explicit calibration, reference values or thresholds requested. Keep depth coverage, units, dates and sampling conditions consistent.

How to use Conductivity Salinity Freshwater Approximation Converter and understand its results

  1. Prepare the observed lake or sample measurements and explicit calibration, reference values or thresholds requested. Keep depth coverage, units, dates and sampling conditions consistent.
  2. Enter observedConductivityMicroS, observedTemperatureC, referenceTemperatureC, callerTempCoefficientPerC, callerSalinityGkgPerReferenceMicroS, callerCalibrationMaximumReferenceMicroS using the field table and calculation rules, then run the tool.
  3. Read referenceNormalizedConductivityMicroS, calibratedFreshwaterSalinityGkg. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
observedConductivityMicroSObserved conductivity micro snumberRequired
observedTemperatureCObserved temperature cnumberRequired
referenceTemperatureCReference temperature cnumberRequired
callerTempCoefficientPerCCaller temp coefficient per cnumberRequired
callerSalinityGkgPerReferenceMicroSCaller salinity gkg per reference micro snumberRequired
callerCalibrationMaximumReferenceMicroSCaller calibration maximum reference micro snumberRequired

Enter nonnegative EC/temperature coefficient, finite temperatures and positive slope/calibration maximum. Require positive factor and normalized EC≤maximum; return reference EC and g/kg.

factor=1+α(observedT−referenceT); referenceEC=observedEC/factor; salinity=referenceEC×slope

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
referenceNormalizedConductivityMicroSReference normalized conductivity micro snumber
calibratedFreshwaterSalinityGkgCalibrated freshwater salinity gkgnumber
json
{
  "input": {
    "observedConductivityMicroS": 100,
    "observedTemperatureC": 20,
    "referenceTemperatureC": 25,
    "callerTempCoefficientPerC": 0.02,
    "callerSalinityGkgPerReferenceMicroS": 0.001,
    "callerCalibrationMaximumReferenceMicroS": 1000
  },
  "output": {
    "referenceNormalizedConductivityMicroS": 111.11111111111111,
    "calibratedFreshwaterSalinityGkg": 0.11111111111111112
  }
}

Limitations and assumptions

No universal seawater practical-salinity, ion-composition or chemistry certification is supplied.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use TDS From Conductivity Calculator: Conductivity and total dissolved solids require a local calibration on a consistent temperature basis. A universal conversion factor cannot describe every ionic mixture. For a complementary task, use Hardness Carbonate Noncarbonate Split Calculator: Hardness and alkalinity can be compared when both use CaCO₃-equivalent units. Alkalinity is not a direct calcium concentration.

References

  1. Conductivity Salinity Freshwater Approximation Converter — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies