Seedling EC Target Lookup
Audit actual final nutrient-solution EC against caller seedling-stage band; distinct from source-water ceiling and temperature compensation, no nutrient-ion sufficiency or universal dosing target.
Description
Final nutrient-solution EC differs from source-water EC.
Final nutrient-solution EC differs from source-water EC. A verified seedling-stage band defines this local check.1
Enter aligned nonempty unique stage IDs/nonnegative minima/maxima, exact query and nonnegative observation list. Validate selected ordered band; return limits and outside indices.
When to use Seedling EC Target Lookup
Use Seedling EC Target Lookup when you need to evaluate the supplied records under the calculation and evidence rules below. Empty observations are allowed. No nutrient sufficiency, universal dosing target or temperature correction is supplied.
Prepare measured container, labor, environmental or inventory records and independently verified stage limits requested. Keep units, temperature conditions and dates consistent.
How to use Seedling EC Target Lookup and understand its results
- Prepare measured container, labor, environmental or inventory records and independently verified stage limits requested. Keep units, temperature conditions and dates consistent.
- Enter callerSeedlingStageIds, callerFinalSolutionEcMinimum, callerFinalSolutionEcMaximum, querySeedlingStageId, observedFinalSolutionEc using the field table and calculation rules, then run the tool.
- Read callerFinalSolutionEcRange, solutionSamplesOutsideCallerEcIndices. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| callerSeedlingStageIds | Caller seedling stage ids | list of string | Required |
| callerFinalSolutionEcMinimum | Caller final solution ec minimum | list of number | Required |
| callerFinalSolutionEcMaximum | Caller final solution ec maximum | list of number | Required |
| querySeedlingStageId | Query seedling stage id | string | Required |
| observedFinalSolutionEc | Observed final solution ec | list of number | Required |
Enter aligned nonempty unique stage IDs/nonnegative minima/maxima, exact query and nonnegative observation list. Validate selected ordered band; return limits and outside indices.
outside=observedEC<selectedMin OR observedEC>selectedMax Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| callerFinalSolutionEcRange | Caller final solution ec range | list of number |
| solutionSamplesOutsideCallerEcIndices | Solution samples outside caller ec indices | list of number |
{
"input": {
"callerSeedlingStageIds": [
"a",
"b"
],
"callerFinalSolutionEcMinimum": [
0.8,
1
],
"callerFinalSolutionEcMaximum": [
1.2,
1.5
],
"querySeedlingStageId": "a",
"observedFinalSolutionEc": [
0.7,
1,
1.3
]
},
"output": {
"callerFinalSolutionEcRange": [
0.8,
1.2
],
"solutionSamplesOutsideCallerEcIndices": [
0,
2
]
}
} Limitations and assumptions
Empty observations are allowed. No nutrient sufficiency, universal dosing target or temperature correction is supplied.
Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Extremely large text inputs are rejected. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use Source Water EC Threshold Lookup: Source-water EC screening needs a verified crop-stage ceiling and known measurements. Missing EC observations are not passing values. For a complementary task, use Slow Release Months Rating Lookup: Release-duration records are tied to measurement temperature. Elapsed time can exceed the rated period and produce a signed deficit.
References
-
Seedling EC Target Lookup — tool.io
Similar or alternative tools
- Source Water EC Threshold Lookup
Source-water EC screening needs a verified crop-stage ceiling and known measurements. Missing EC observations are not passing values.
- Slow Release Months Rating Lookup
Release-duration records are tied to measurement temperature. Elapsed time can exceed the rated period and produce a signed deficit.