Pelvic Image Reference Plane Flag Tool

Compare supplied exact plane-normal vectors without assigning anatomy or claiming tolerance-based image registration.

Loading tool…

Description

Test exact zero cross-product for parallel, positive dot product for sameDirection, and accept parallel vectors under the supplied opposite-direction policy.

Research image measurements depend on scale, orientation, landmarks, and reference planes. A coordinate or area-support calculation uses supplied inputs without examining an image or identifying anatomy.

Test exact zero cross-product for parallel, positive dot product for sameDirection, and accept parallel vectors under the supplied opposite-direction policy.

When to use this tool

Use Pelvic Image Reference Plane Flag when you need one transparent image-scale or orientation component.

How to use the tool and how it works

  1. Enter normal, reference, allowOpposite. Keep parallel arrays aligned. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read parallel, sameDirection, accepted. Inspect parallel, sameDirection, accepted before interpreting the associated values.

Require nonzero three-component normal and reference vectors. Test exact zero cross-product for parallel, positive dot product for sameDirection, and accept parallel vectors under the supplied opposite-direction policy.1

Input fieldMeaning and unitsAccepted input
normalNormalRequired. Array of finite number; maximum items 256.
referenceSupplied reference token under the supported grammar.Required. Array of finite number; maximum items 256.
allowOppositeAllow OppositeRequired. Boolean.
Output fieldInterpretationReturned shape
parallelParallelRequired. Boolean.
sameDirectionWhether the normals have a positive dot product; this alone does not establish parallelism.Required. Boolean.
acceptedAcceptedRequired. Boolean.
json
{
  "input": {
    "normal": [
      0,
      0,
      1
    ],
    "reference": [
      0,
      0,
      -1
    ],
    "allowOpposite": true
  },
  "output": {
    "parallel": true,
    "sameDirection": false,
    "accepted": true
  }
}

Limitations and assumptions

  • No numerical tolerance is used; sameDirection can be true without parallel, and floating-point limits can affect the check. Plane location, image registration, anatomical orientation, and diagnosis are not evaluated.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Verify image calibration, anatomical reference conventions, measurement uncertainty, and professional interpretation separately.

References

  1. Calculation and input contract: gynecology/pelvic-image-reference-plane-flag — tool.io

Similar or alternative tools

  • Specimen Side Clockface Source Pair

    Map clock position to degrees clockwise from twelve, reverse the angle when mirrored, compare views literally, and serialize side, view, and clock position as sourceKey.

  • Pelvic Image Support Share

    Sum visible area and the visible subset with both support flags, returning their ratio or zero with defined false.