Skip to content

Main content

Rock Powder Dilution Blank Correction Tool

Blank-corrected digest concentration converted to sample mass basis in caller-consistent units; negative blanks-corrected results are retained.

Loading tool…

Description

Subtract blankConcentration from measuredConcentration, then multiply by dilution factor and digest volume and divide by sample mass.

Geochemical mass calculations distinguish wet sample, dry sample, ash, digest, and crucible-inclusive measurements. Moisture fractions and dilution factors change the reporting basis; they do not establish recovery, analyte retention, or laboratory accuracy.

Subtract blankConcentration from measuredConcentration, then multiply by dilution factor and digest volume and divide by sample mass.

When to use this tool

Use Rock Powder Dilution Blank Correction when you need an explicit sample-mass or concentration-basis calculation.

How to use the tool and how it works

  1. Enter measuredConcentration, blankConcentration, dilutionFactor, digestVolume, sampleMass. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read blankCorrected, sampleConcentration. Use the output convention below.

Require positive dilutionFactor, digestVolume, and sampleMass. Subtract blankConcentration from measuredConcentration, then multiply by dilution factor and digest volume and divide by sample mass.1

Input fieldMeaning and unitsAccepted input
measuredConcentrationMeasured ConcentrationRequired. Finite number.
blankConcentrationBlank ConcentrationRequired. Finite number.
dilutionFactorPositive factor multiplying the blank-corrected digest concentration.Required. Finite number; strictly above 0.
digestVolumeDigest VolumeRequired. Finite number; strictly above 0.
sampleMassSample MassRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
blankCorrectedBlank CorrectedRequired. Finite number.
sampleConcentrationBlank-corrected analyte mass per sample mass with dimensionally compatible inputs.Required. Finite number.
json
{
  "input": {
    "measuredConcentration": 12,
    "blankConcentration": 2,
    "dilutionFactor": 5,
    "digestVolume": 0.1,
    "sampleMass": 0.01
  },
  "output": {
    "blankCorrected": 10,
    "sampleConcentration": 500
  }
}

Limitations and assumptions

  • Concentrations, volume, and mass must be dimensionally compatible so the result is analyte mass per sample mass. A negative blank-corrected result is retained; no detection-limit substitution, digestion recovery, or uncertainty correction is applied.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Check the analytical preparation and measurement records for blanks, recovery, moisture, and mass basis. Use the laboratory's validated procedure for actual sample interpretation.

References

  1. Calculation and input contract: geochemistry/rock-powder-dilution-blank-correction — tool.io