Description
energyTerm = mutual*firstCurrent*secondCurrent, negated when aiding is false.
Magnetic coupling uses explicit winding, current and voltage references. Turns-square reflection and mutual-energy signs are ideal model conventions; they do not establish actual coupling, saturation or a safe winding connection.
energyTerm = mutual*firstCurrent*secondCurrent, negated when aiding is false.
When to use this tool
Use Magnetically Coupled Inductor Energy Cross Term when checking one supplied turns-ratio, dot-reference or mutual-coupling term.
How to use the tool and how it works
- Enter mutual, firstCurrent, secondCurrent, aiding. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read energyTerm. Use the output convention below.
Require nonnegative mutual inductance. energyTerm = mutual*firstCurrent*secondCurrent, negated when aiding is false.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| mutual | Mutual | Required. Finite number; minimum 0. |
| firstCurrent | First Current | Required. Finite number. |
| secondCurrent | Second Current | Required. Finite number. |
| aiding | Aiding | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| energyTerm | Mutual cross-energy term only, not total coupled-inductor stored energy. | Required. Finite number. |
{
"input": {
"mutual": 0.2,
"firstCurrent": 2,
"secondCurrent": 3,
"aiding": true
},
"output": {
"energyTerm": 1.2000000000000002
}
} Limitations and assumptions
- Use henries and amperes for joules. This is only the mutual cross term, without individual self energies or a check that the coupled-inductor parameters are physically realizable.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use the full coupled circuit and component data for physical realizability, losses, transients and operating constraints.