Description
Convert a supplied liquid amount into ideal-gas volume.
Cryogenic measurements and budgets depend on the fluid state, absolute temperatures and pressure reference, as well as compatible units. Local mass, heat or ideal-gas terms describe a supplied model without determining actual material properties or safe equipment operation.
Convert a supplied liquid amount into ideal-gas volume.
When to use this tool
Use Boiloff Liquid Mass Gas Volume Factor when checking a supplied cryogenic measurement, reference-state conversion or engineering budget.
How to use the tool and how it works
- Enter liquidVolume, liquidDensity, gasMolarMass, gasConstant, gasTemperatureK, gasPressure. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read mass, moles, gasVolume. Use the output convention below.
Convert a supplied liquid amount into ideal-gas volume. Require liquidVolume >= 0 and positive density, molar mass, gas constant, absolute pressure and kelvin temperature; mass = volume*density, moles = mass/molarMass, gasVolume = moles*R*T/P.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| liquidVolume | Liquid Volume | Required. Finite number; minimum 0. |
| liquidDensity | Liquid Density | Required. Finite number; strictly above 0. |
| gasMolarMass | Positive gas molar mass, such as kg/mol with an SI gas constant. | Required. Finite number; strictly above 0. |
| gasConstant | Gas Constant | Required. Finite number; strictly above 0. |
| gasTemperatureK | Gas Temperature K | Required. Finite number; strictly above 0. |
| gasPressure | Positive absolute gas pressure, such as Pa for SI output. | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| mass | Mass | Required. Finite number. |
| moles | Moles | Required. Finite number. |
| gasVolume | Gas Volume | Required. Finite number. |
{
"input": {
"liquidVolume": 0.01,
"liquidDensity": 800,
"gasMolarMass": 0.028,
"gasConstant": 8.31446261815324,
"gasTemperatureK": 300,
"gasPressure": 100000
},
"output": {
"mass": 8,
"moles": 285.7142857142857,
"gasVolume": 7.126682244131349
}
} Limitations and assumptions
- Use a mutually consistent unit system, such as kg, kg/mol, Pa and J/(mol K); real-gas and phase behavior are omitted.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use verified state-specific properties and a complete qualified engineering assessment for practical cryogenic design, filling and handling.
References
Similar or alternative tools
- Boiloff Gas Basis Pressure Factor
Rescale boiloff gas volume to a reference basis.
- Cryogen Vent Volume Reference Factor
Convert a supplied gas volume to reference pressure and temperature.