Ion Valence Potential Sign Tool

Formal electrostatic energy difference using a caller-supplied charge unit and voltage sign.

Loading tool…

Description

Return electrostatic energy change and sign.

Membrane electrical quantities distinguish total from area-specific properties, concentration ratios from activities and single-ion from multi-ion models. Local capacitance, current or potential terms require compatible sign, valence, temperature and unit conventions without themselves validating a biological membrane.

Return electrostatic energy change and sign.

When to use this tool

Use Ion Valence Potential Sign when evaluating the stated membrane, ionic or area-basis term.

How to use the tool and how it works

  1. Enter valence, potentialDifference, elementaryCharge. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read energyChange, energySign. Use the output convention below.

Return electrostatic energy change and sign. Require whole signed valence and elementaryCharge > 0; energyChange = valence*charge*potentialDifference, energySign is the product of the two signed factors.1

Input fieldMeaning and unitsAccepted input
valenceSigned whole charge count; zero is accepted and produces zero energy change.Required. Safe integer.
potentialDifferencePotential DifferenceRequired. Finite number.
elementaryChargeElementary ChargeRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
energyChangeEnergy ChangeRequired. Finite number.
energySignEnergy SignRequired. Safe integer.
json
{
  "input": {
    "valence": 2,
    "potentialDifference": -0.1,
    "elementaryCharge": 1
  },
  "output": {
    "energyChange": -0.2,
    "energySign": -1
  }
}

Limitations and assumptions

  • Use potential difference in the intended direction; zero valence is accepted and gives zero, without establishing ion identity or membrane behavior.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified concentrations, activities, geometry and electrical calibration with the appropriate complete membrane/channel model for physiological interpretation.

References

  1. Calculation and input contract: biophysics/ion-valence-potential-sign — tool.io