Description
Return ideal-gas ozone molar and mass density.
Gas-sampling conversions distinguish actual from reference volume, wet from dry composition and total from partial pressure. A supplied ideal-gas or constant-flow factor requires compatible units and state definitions without validating actual sampling conditions or exposure.
Return ideal-gas ozone molar and mass density.
When to use this tool
Use Ozone Mixing Ratio Mass Density Term when checking the stated gas state, sampling-volume or flow-basis conversion.
How to use the tool and how it works
- Enter moleFraction, pressurePa, molarMassKgPerMol, temperatureK, gasConstant. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read molarDensity, massDensity. Use the output convention below.
Return ideal-gas ozone molar and mass density. Require fraction in [0,1], pressurePa >= 0 and positive molarMassKgPerMol, temperatureK and gasConstant; molarDensity = fraction*P/(R*T), massDensity multiplies molar mass.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| moleFraction | Mole Fraction | Required. Finite number; minimum 0; maximum 1. |
| pressurePa | Pressure Pa | Required. Finite number; minimum 0. |
| molarMassKgPerMol | Molar Mass Kg Per Mol | Required. Finite number; strictly above 0. |
| temperatureK | Temperature K | Required. Finite number; strictly above 0. |
| gasConstant | Molar SI gas constant in J/(mol K). | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| molarDensity | Molar Density | Required. Finite number. |
| massDensity | kg/m³ when pressure is Pa, temperature K and molarMassKgPerMol kg/mol. | Required. Finite number. |
{
"input": {
"moleFraction": 0.000001,
"pressurePa": 100000,
"molarMassKgPerMol": 0.048,
"temperatureK": 300,
"gasConstant": 8
},
"output": {
"molarDensity": 0.000041666666666666665,
"massDensity": 0.000002
}
} Limitations and assumptions
- R must be molar SI gas constant for mol/m³ and kg/m³ outputs; gas identity, nonideality and health interpretation are not verified.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use verified absolute pressure/temperature, humidity and flow calibration with the appropriate real-gas/sampling model when ideal assumptions are inadequate.
References
Similar or alternative tools
- Standard Flow Volume Ratio
Return ideal-gas standard/actual volume ratio.
- Gas Sample Humidity Volume Correction
Return dry-volume equivalent from wet sample volume.