Description
Return linear soffit height and local floor clearance.
Architectural openings and clearances depend on measured boundaries, projection axes and a caller-supplied comparison criterion. A positive geometric margin is distinct from demonstrating code compliance, safe access or a complete door-swing envelope. Plan lengths and projected dimensions must not be mistaken for full spatial measurements.
Return linear soffit height and local floor clearance.
When to use this tool
Use Soffit Slope Clearance At Point when checking the stated opening, projection or clearance geometry.
How to use the tool and how it works
- Enter startHeight, gradient, distance, floorHeight. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read soffitHeight, clearance. Use the output convention below.
Return linear soffit height and local floor clearance. soffitHeight = startHeight+gradient*distance, clearance subtracts floorHeight.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| startHeight | Start Height | Required. Finite number. |
| gradient | Gradient | Required. Finite number. |
| distance | Distance | Required. Finite number. |
| floorHeight | Floor Height | Required. Finite number. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| soffitHeight | Soffit Height | Required. Finite number. |
| clearance | Clearance | Required. Finite number. |
{
"input": {
"startHeight": 3,
"gradient": -0.1,
"distance": 4,
"floorHeight": 0.2
},
"output": {
"soffitHeight": 2.6,
"clearance": 2.4
}
} Limitations and assumptions
- Distance and gradient use a compatible signed axis; actual profile, headroom adequacy and code compliance are not established.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use complete measured plans and a qualified architectural/engineering assessment with the applicable requirements for real construction or safety decisions.
References