Skip to content

Main content

Pond Drain Volume Residual Tool

Calculate pond drain volume residual from explicit caller-supplied inputs.

Loading tool…

Description

Return nominal pond closing volume and residual.

Aquaculture material budgets distinguish as-fed mass, dry mass, specific energy and nutrient fractions. Offered feed, recovered feed and estimated intake are different quantities. Arithmetic balances do not determine biological utilization, an appropriate diet, disease status or a safe feeding recommendation.

Return nominal pond closing volume and residual.

When to use this tool

Use Pond Drain Volume Residual when checking the stated aquaculture feed, material or composition basis.

How to use the tool and how it works

  1. Enter opening, inflow, pumpedOut, evaporated, measuredClosing. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read predictedClosing, residual. Use the output convention below.

Return nominal pond closing volume and residual. Require nonnegative amounts; predictedClosing = opening+inflow-pumpedOut-evaporated, residual = measured-predicted.1

Input fieldMeaning and unitsAccepted input
openingOpeningRequired. Finite number; minimum 0.
inflowInflowRequired. Finite number; minimum 0.
pumpedOutPumped OutRequired. Finite number; minimum 0.
evaporatedEvaporatedRequired. Finite number; minimum 0.
measuredClosingMeasured ClosingRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
predictedClosingPredicted ClosingRequired. Finite number.
residualSigned observed/calculated-minus-reference difference under the operation specified above.Required. Finite number.
json
{
  "input": {
    "opening": 100,
    "inflow": 20,
    "pumpedOut": 50,
    "evaporated": 5,
    "measuredClosing": 60
  },
  "output": {
    "predictedClosing": 65,
    "residual": -5
  }
}

Limitations and assumptions

  • Negative predictions are retained; leakage, rainfall, storage geometry and actual safe operating conditions are not resolved.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use verified feed and animal records, representative measurements and qualified aquaculture/veterinary advice for actual nutrition, welfare or water-quality decisions.

References

  1. Calculation and input contract: aquaculture/pond-drain-volume-residual — tool.io

Similar or alternative tools