Internal Control Ct Delay
Screen sample internal-control Ct delay against the median reference and a supplied tolerance; delay is not specific for inhibition.
Description
Compare a sample’s internal-control Ct with the median reference Ct and flag delay strictly above a supplied cycle tolerance.
In quantitative PCR, a threshold cycle, commonly called Ct, records when amplification reaches a defined signal threshold. An internal control helps monitor aspects of the analytical process. Comparing its Ct with reference controls can reveal a delayed signal that deserves assay review.1
A delay can arise from inhibition or other differences in input, extraction, or amplification conditions. This tool defines delay as sample-control Ct minus the median of supplied reference-control Cts, keeping that signed difference separate from the flag.
Internal Control Ct Delay returns the reference median, delay in cycles, and a boolean based on your maximum tolerance. The field name inhibitionFlag represents this screening comparison, not a demonstrated cause.
When to screen internal-control shifts
Use the tool with comparable sample and reference control measurements from a defined assay. Choose the tolerance outside the calculator and retain the assay’s control interpretation rules.
- Summarize several reference Cts with a median.
- Apply a consistent maximum-delay comparison to a sample.
How to enter control Cts and calculate delay
- Enter positive Sample control ct and a nonempty Reference control cts list of positive finite values.
- Enter nonnegative Maximum delay cycles.
- Run the screen and read Reference median ct, Delay cycles, and Inhibition flag.
- Review a flagged result with the underlying assay controls and procedure.
delayCycles = sampleControlCt − median(referenceControlCts); inhibitionFlag = delayCycles > maximumDelayCycles The implementation sorts a copy of the reference list. For an even count it averages the middle two values. Equality with the maximum is not flagged.
{
"input": {
"sampleControlCt": 30,
"referenceControlCts": [
25,
26,
27
],
"maximumDelayCycles": 2
},
"output": {
"referenceMedianCt": 26,
"delayCycles": 4,
"inhibitionFlag": true
}
} A sample Ct below the median gives a negative delay and is not flagged by this rule. Empty references, nonpositive Cts, negative tolerance, and malformed or nonfinite inputs produce errors.
Limitations and interpretation
- No diagnosis of inhibition, target concentration, control recovery, or assay validity follows from the comparison alone.
- The tool uses supplied controls without run matching, outlier removal, amplification-efficiency correction, or uncertainty estimates.
- An undetected control cannot be entered as a missing Ct or a made-up numeric ceiling without changing the analysis.
- The tolerance is caller-defined; no assay-specific cutoff is built in.
Alternative or Complementary methods
Control shifts are one element of a broader assay review. A batch-screen record audit distinguishes missing tests and invalid-control flags, while a fitted detection-limit inversion answers a different analytical question.
References
-
The MIQE guidelines: minimum information for publication of quantitative real-time PCR experiments — Clinical Chemistry; S. A. Bustin and colleagues (2009)
Similar or alternative tools
- RCL Batch Screen Audit
Audit required tests alongside supplied negative-result and valid-control flags.
- Probit Detection Limit
Invert a separately fitted probit model for a target detection probability.