Description
For nonnegative finishedMass, carrierFraction, and waterFraction with sum<=1 and nonnegative declaredNativeMass return nativeMass=finishedMass*(1-carrierFraction-waterFraction), carrierMass=finishedMass*carrierFraction, and nativeDiscrepancy=nativeMass-declaredNativeMass.
Botanical laboratory records distinguish wet mass, dry matter, carriers, extract mass, and assay response. A fraction or reference comparison depends on the chosen material basis and supplied analytical method. Voucher and monograph metadata help identify records but do not themselves authenticate a specimen or establish product quality.
For nonnegative finishedMass, carrierFraction, and waterFraction with sum<=1 and nonnegative declaredNativeMass return nativeMass=finishedMass*(1-carrierFraction-waterFraction), carrierMass=finishedMass*carrierFraction, and nativeDiscrepancy=nativeMass-declaredNativeMass.
When to use this tool
Use Botanical Extract Carrier Mass Deduction when you need this mass-basis, assay-response, extraction, or source-record calculation for supplied laboratory data.
How to use the tool and how it works
- Enter finishedMass, carrierFraction, waterFraction, declaredNativeMass. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read nativeMass, carrierMass, nativeDiscrepancy. Use the output convention below.
For nonnegative finishedMass, carrierFraction, and waterFraction with sum<=1 and nonnegative declaredNativeMass return nativeMass=finishedMass*(1-carrierFraction-waterFraction), carrierMass=finishedMass*carrierFraction, and nativeDiscrepancy=nativeMass-declaredNativeMass.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| finishedMass | Finished Mass | Required. Finite number; minimum 0. |
| carrierFraction | Carrier mass fraction of the stated finished-mass base. | Required. Finite number; minimum 0. |
| waterFraction | Water mass fraction of the stated gross or finished mass. | Required. Finite number; minimum 0. |
| declaredNativeMass | Declared Native Mass | Required. Finite number; minimum 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| nativeMass | Native Mass | Required. Finite number. |
| carrierMass | Carrier Mass | Required. Finite number. |
| nativeDiscrepancy | Native Discrepancy | Required. Finite number. |
{
"input": {
"finishedMass": 100,
"carrierFraction": 0.2,
"waterFraction": 0.1,
"declaredNativeMass": 68
},
"output": {
"nativeMass": 70,
"carrierMass": 20,
"nativeDiscrepancy": 2
}
} Limitations and assumptions
- Fractions share the finished-mass base and must represent distinct components. The remaining mass is a supplied composition model, not proof of extract identity, purity, or compliance.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Use the appropriate authenticated reference material, analytical protocol, and source records for a full laboratory assessment. Verify moisture basis, response factors, and extract/carrier definitions before comparing results.
References
Similar or alternative tools
- Extract Carrier Mass Exclusion
Supplied extract/carrier ledger arithmetic without preparation instructions or therapeutic claims.
- Botanical Extract Drug Extract Ratio Factor
Distinguish supplied native and carrier-containing extract mass ratios.