Fluoride-Fiber Window Margin
Compare a thulium-fluoride operating wavelength with caller-supplied transmission-window bounds.
Description
A fluoride-fiber wavelength screen uses caller-supplied transmission-window endpoints.
A fluoride-fiber wavelength screen uses caller-supplied transmission-window endpoints. Edge margins identify which bound is exceeded.1
Compare a thulium-fluoride operating wavelength with caller-supplied transmission-window bounds.
When to use Fluoride-Fiber Window Margin
Use this tool to compare a thulium-fluoride operating wavelength with caller-supplied transmission-window bounds.
Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.
How to use Fluoride-Fiber Window Margin and understand its results
- Prepare the optical measurements, geometry, fitted coefficients or caller-selected thresholds requested. Confirm wavelength, radius/diameter, pulse-width, angle and unit conventions before running the calculation.
- Enter operatingWavelengthNanometers, minimumWindowNanometers, maximumWindowNanometers using the field table and calculation rules, then run the tool.
- Read lowerMarginNanometers, upperMarginNanometers, withinWindow. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| operatingWavelengthNanometers | Operating wavelength (nm) | number; minimum: 0 | Required |
| minimumWindowNanometers | Minimum transmission-window wavelength (nm) | number; minimum: 0 | Required |
| maximumWindowNanometers | Maximum transmission-window wavelength (nm) | number; minimum: 0 | Required |
Enter nonnegative wavelengths with ordered bounds. Return margins and inclusive within-window flag; equal bounds admit only that wavelength.
lowerMargin=operating−minimum; upperMargin=maximum−operating Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| lowerMarginNanometers | Lower-window margin (nm) | number |
| upperMarginNanometers | Upper-window margin (nm) | number |
| withinWindow | Within window | boolean |
{
"input": {
"operatingWavelengthNanometers": 2350,
"minimumWindowNanometers": 1800,
"maximumWindowNanometers": 2500
},
"output": {
"lowerMarginNanometers": 550,
"upperMarginNanometers": 150,
"withinWindow": true
}
} Limitations and assumptions
No material transmission spectrum, gain or attenuation threshold is embedded.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.
Alternative or Complementary methods
Use HDFA Window Margin: Check a wavelength against caller-supplied holmium-fiber amplifier window bounds. For a complementary task, use TDFA Band Overlap: Calculate overlap between TDFA gain and a requested signal band.
References
-
Fluoride-Fiber Window Margin — tool.io
Similar or alternative tools
- HDFA Window Margin
Check a wavelength against caller-supplied holmium-fiber amplifier window bounds.
- TDFA Band Overlap
Calculate overlap between TDFA gain and a requested signal band.