TAD Boundary Distance

Measure adjacent TAD boundary distances.

Description

TAD boundary spacing summarizes positions already assigned as boundaries.

TAD boundary spacing summarizes positions already assigned as boundaries.1

Measure adjacent TAD boundary distances.

When to use TAD Boundary Distance

Use this tool to measure adjacent TAD boundary distances.

Prepare the already measured signals, counts, coordinates, fitted coefficients or sequence strings requested. Keep assay definitions, units, aligned lists and caller-selected thresholds consistent.

How to use TAD Boundary Distance and understand its results

  1. Prepare the already measured signals, counts, coordinates, fitted coefficients or sequence strings requested. Keep assay definitions, units, aligned lists and caller-selected thresholds consistent.
  2. Enter tadBoundaryPositionsBp using the field table and calculation rules, then run the tool.
  3. Read adjacentDistancesBp, meanDistanceBp, minimumDistanceBp. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
tadBoundaryPositionsBpTAD boundary positions (bp)list of numberRequired

Enter at least two strictly increasing finite positions; return adjacent gaps, mean and minimum.

gap[i]=boundary[i+1]−boundary[i]

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
adjacentDistancesBpAdjacent boundary distances (bp)list of number
meanDistanceBpMean TAD boundary distance (bp)number; minimum: 0
minimumDistanceBpMinimum boundary distance (bp)number; minimum: 0
json
{
  "input": {
    "tadBoundaryPositionsBp": [
      0,
      100,
      300
    ]
  },
  "output": {
    "adjacentDistancesBp": [
      100,
      200
    ],
    "meanDistanceBp": 150,
    "minimumDistanceBp": 100
  }
}

Limitations and assumptions

Signed/fractional coordinates are accepted. No chromosome or domain detection is performed.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.

Alternative or Complementary methods

Use Insulation Local Minimum: Find the lowest insulation score within an interior search range. For a complementary task, use DMR Window Merger: Merge adjacent DMR windows within a selected distance.

References

  1. TAD Boundary Distance — tool.io

Similar or alternative tools

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies