Treatment Stage Load Reduction Tool

Compare supplied stage mass-flow loads while retaining signed background-corrected concentrations.

Loading tool…

Description

Compute inletLoadRate = inletConcentration*inletFlow, outletLoadRate = outletConcentration*outletFlow and removedLoadRate = inletLoadRate-outletLoadRate.

A pollutant load combines concentration with a compatible flow, volume or activity factor. A load rate has amount-per-time units, whereas an integrated load also includes duration; concentration differences alone do not describe removal when flows differ.

Compute inletLoadRate = inletConcentration*inletFlow, outletLoadRate = outletConcentration*outletFlow and removedLoadRate = inletLoadRate-outletLoadRate.

When to use this tool

Use Treatment Stage Load Reduction when checking one supplied emission, transport or treatment mass-balance contribution.

How to use the tool and how it works

  1. Enter inletConcentration, inletFlow, outletConcentration, outletFlow. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read inletLoadRate, outletLoadRate, removedLoadRate, fraction, defined. Inspect defined before interpreting the associated values.

Require nonnegative inletFlow and outletFlow. Compute inletLoadRate = inletConcentration*inletFlow, outletLoadRate = outletConcentration*outletFlow and removedLoadRate = inletLoadRate-outletLoadRate. For a nonzero inlet load return fraction = 1-outletLoadRate/inletLoadRate and defined = true; otherwise fraction = 0 and defined = false.1

Input fieldMeaning and unitsAccepted input
inletConcentrationInlet ConcentrationRequired. Finite number.
inletFlowInlet FlowRequired. Finite number; minimum 0.
outletConcentrationOutlet ConcentrationRequired. Finite number.
outletFlowOutlet FlowRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
inletLoadRateInlet Load RateRequired. Finite number.
outletLoadRateOutlet Load RateRequired. Finite number.
removedLoadRateRemoved Load RateRequired. Finite number.
fractionDimensionless ratio under the stated denominator convention; not multiplied by 100.Required. Finite number.
definedWhether the denominator is positive and the returned ratio is defined; inspect this before using a zero placeholder.Required. Boolean.
json
{
  "input": {
    "inletConcentration": 10,
    "inletFlow": 2,
    "outletConcentration": 3,
    "outletFlow": 2
  },
  "output": {
    "inletLoadRate": 20,
    "outletLoadRate": 6,
    "removedLoadRate": 14,
    "fraction": 0.7,
    "defined": true
  }
}

Limitations and assumptions

  • Concentrations are signed finite inputs, so the tool does not enforce physically nonnegative loads or clamp removal to [0,1]. Use matching mass/time units and comparable periods; no storage, degradation or full treatment mass balance is inferred.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Integrate changing measurements over time and reconcile storage and reactions when a constant-condition product is insufficient.

References

  1. Calculation and input contract: environmental-engineering/treatment-stage-load-reduction — tool.io

Similar or alternative tools

  • Treatment Load Baseline Gap

    Return removedLoad = inletLoad-outletLoad, measuredRemovalFraction = removedLoad/inletLoad and residualLoadGap = outletLoad-inletLoad*(1-baselineRemovalFraction).

  • Treatment Bypass Mass Term Tool

    Integrate a constant explicitly supplied bypass stream load in compatible units without regulatory interpretation.