Composite Sample Flow Proportional Aliquot Tool

Allocate one explicit composite sample aliquot in proportion to a supplied interval flow weight without choosing sampling times.

Loading tool…

Description

Allocate one composite-sample aliquot by a supplied flow weight.

Composite sampling allocates a target volume across represented intervals using a declared weight basis. A weight may need flow integrated over time rather than a single flow reading, depending on the design. A local proportional aliquot is one part of a sampling plan, not verification of representativeness or analytical suitability.

Allocate one composite-sample aliquot by a supplied flow weight.

When to use this tool

Use Composite Sample Flow Proportional Aliquot when you already have targetCompositeVolume, intervalFlowWeight, totalFlowWeight and need to allocate one composite-sample aliquot by a supplied flow weight.

How to use the tool and how it works

  1. Enter targetCompositeVolume, intervalFlowWeight, totalFlowWeight. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read aliquotVolume. Use the output convention below.

Require target volume>=0, totalFlowWeight>0 and interval weight within total; return target*(intervalWeight/totalWeight).1

Input fieldMeaning and unitsAccepted input
targetCompositeVolumeTarget Composite VolumeRequired. Finite number; minimum 0.
intervalFlowWeightNonnegative time-supported flow weight in the same basis as totalFlowWeight; do not mix unequal-duration raw rates without weighting.Required. Finite number; minimum 0.
totalFlowWeightTotal Flow WeightRequired. Finite number; strictly above 0.
Output fieldInterpretationReturned shape
aliquotVolumeAliquot VolumeRequired. Finite number.
json
{
  "input": {
    "targetCompositeVolume": 1000,
    "intervalFlowWeight": 30,
    "totalFlowWeight": 120
  },
  "output": {
    "aliquotVolume": 250
  }
}

Limitations and assumptions

  • Weights must use a consistent basis and time support; no actual flow, complete sample, analyte validity or appropriate sampling protocol is determined.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use the actual flow record, interval durations and complete sampling design to construct a composite. Reconcile all aliquots and analytical requirements; one proportional allocation does not validate the full sample or select a protocol.

References

  1. Calculation and input contract: environmental-engineering/composite-sample-flow-proportional-aliquot — tool.io