Varistor Clamping Voltage
Estimate MOV clamping voltage at a specified current from a calibrated power-law V–I curve V=Vref(I/Iref)^(1/alpha); alpha must come from device data.
Description
Estimate MOV clamping voltage at a specified current from a calibrated power-law V–I curve V=Vref(I/Iref)^(1/alpha); alpha must come from device data.
Varistor Clamping Voltage: Estimate MOV clamping voltage at a specified current from a calibrated power-law V–I curve V=Vref(I/Iref)^(1/alpha); alpha must come from device data.
When to use Varistor Clamping Voltage
Use this electronics calculation for a first-pass component, converter, signal, motor, or sensor estimate when the stated operating conditions and units match the device data.
- Reference (V) (V)
- Required number input.
- Reference Current (A) (A)
- Required number input.
- Pulse Current (A) (A)
- Required number input.
- Nonlinearity Exponent
- Required number input.
How Varistor Clamping Voltage works
Estimate MOV clamping voltage at a specified current from a calibrated power-law V–I curve V=Vref(I/Iref)^(1/alpha); alpha must come from device data. The tool evaluates the supplied inputs together and returns the named outputs below; it does not infer omitted operating conditions or change the units shown.1
- Clamping (V) (V)
- The resulting clamping (v) returned as a number.
Limitations and assumptions
- TVS, varistor, and Zener protection depends on surge waveform, source impedance, clamping current, dynamic resistance, parasitic inductance, temperature, repetition, energy rating, tolerance, and degradation. Nominal voltage is not the protected-node peak.
- Use finite inputs in the displayed units and preserve more precision than the final presentation requires. Independently verify safety-critical, financial, compliance, or production decisions.
Alternative or Complementary approaches
Check the result against the current datasheet and worst-case operating corners, then verify the circuit or measurement with simulation and bench testing where failure matters.
References
-
Transient-voltage-suppression diode — Wikipedia contributors
Similar or alternative tools
- TVS Peak Pulse Power
Calculate peak transient-voltage-suppressor pulse power as clamping voltage multiplied by peak pulse current at the same point on the device curve.
- Esd Clamping Voltage
Estimate ESD protection clamping voltage with a fitted dynamic-resistance model V=Vbr+I Rd; use device pulse-current data for the chosen waveform.
- Opamp Short Circuit Power
Estimate output-stage dissipation during an op-amp short to ground as supply-to-short voltage magnitude times the measured short-circuit current; this is not total device power.