Reed Switch Operate Distance Calculator

Infer bracketed reed operate distance on caller calibrated axial magnetic field versus distance; absent crossing retains unknown zero sentinel, no universal magnet inverse-power law, release hysteresis or installation range guarantee.

Description

Reed operate distance can be bracketed on a measured axial-field curve.

Reed operate distance can be bracketed on a measured axial-field curve. Lack of a crossing should remain explicitly unknown.1

Enter nonnegative strictly increasing distances and aligned nonnegative strictly decreasing fields with at least two points, plus positive threshold. Return crossing value and found flag, with zero as absent sentinel and the observed distance domain.

When to use Reed Switch Operate Distance Calculator

Use Reed Switch Operate Distance Calculator when you need to evaluate the supplied records under the calculation and evidence rules below. No universal magnet-distance law, release hysteresis or installation guarantee is supplied.

Prepare measured device or circuit evidence with matched frequency, temperature, waveform and calibration conditions. Supply explicit caller ratings and limits.

How to use Reed Switch Operate Distance Calculator and understand its results

  1. Prepare measured device or circuit evidence with matched frequency, temperature, waveform and calibration conditions. Supply explicit caller ratings and limits.
  2. Enter magnetDistancesMm, calibratedAxialFieldMillitesla, callerReedOperateFieldMillitesla using the field table and calculation rules, then run the tool.
  3. Read bracketedOperateDistanceMm, operateThresholdBracketed, observedDistanceDomainMm. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
magnetDistancesMmMagnet distances mmlist of numberRequired
calibratedAxialFieldMilliteslaCalibrated axial field milliteslalist of numberRequired
callerReedOperateFieldMilliteslaCaller reed operate field milliteslanumberRequired

Enter nonnegative strictly increasing distances and aligned nonnegative strictly decreasing fields with at least two points, plus positive threshold. Return crossing value and found flag, with zero as absent sentinel and the observed distance domain.

distance=piecewise-linear crossing(field,operateThreshold)

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
bracketedOperateDistanceMmBracketed operate distance mmnumber
operateThresholdBracketedOperate threshold bracketedboolean
observedDistanceDomainMmObserved distance domain mmlist of number
json
{
  "input": {
    "magnetDistancesMm": [
      1,
      2,
      3
    ],
    "calibratedAxialFieldMillitesla": [
      9,
      6,
      3
    ],
    "callerReedOperateFieldMillitesla": 5
  },
  "output": {
    "bracketedOperateDistanceMm": 2.3333333333333335,
    "operateThresholdBracketed": true,
    "observedDistanceDomainMm": [
      1,
      3
    ]
  }
}

Limitations and assumptions

No universal magnet-distance law, release hysteresis or installation guarantee is supplied.

Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.

Alternative or Complementary methods

Use Proximity Sensor Range Calculator: A sensor range criterion can be located on target-specific measured detection fractions. Observed range endpoints expose censoring. For a complementary task, use Hall Sensor Switch Point Calculator: A Hall Schmitt switch keeps state between operate and release thresholds. Initial state therefore matters.