PoE Delivered Power Budget

Estimate delivered PoE power as source power minus I²R cable loss and other fixed losses. Use the full loop resistance of the powered conductor pairs; protocol class and startup margins are not modeled.

Description

Estimate delivered PoE power as source power minus I²R cable loss and other fixed losses. Use the full loop resistance of the powered conductor pairs; protocol class and startup margins are not modeled.

PoE Delivered Power Budget: Estimate delivered PoE power as source power minus I²R cable loss and other fixed losses. Use the full loop resistance of the powered conductor pairs; protocol class and startup margins are not modeled.

When to use PoE Delivered Power Budget

Use this electronics calculation for a first-pass component, converter, signal, motor, or sensor estimate when the stated operating conditions and units match the device data.

Source power (W)
Required number input.
Cable current (A)
Required number input.
Loop resistance (Ω)
Required number input.
Other loss (W)
Required number input.

How PoE Delivered Power Budget works

Estimate delivered PoE power as source power minus I²R cable loss and other fixed losses. Use the full loop resistance of the powered conductor pairs; protocol class and startup margins are not modeled. The tool evaluates the supplied inputs together and returns the named outputs below; it does not infer omitted operating conditions or change the units shown.1

Cable Loss W
The resulting cable loss w returned as a number.
Delivered Power W
The resulting delivered power w returned as a number.

Limitations and assumptions

  • PoE power budgets must match the IEEE class, power at the sourcing and powered-device interfaces, pair set, cable resistance, temperature, startup classification, and conversion efficiency. Nominal switch power does not guarantee power at every endpoint.
  • Use finite inputs in the displayed units and preserve more precision than the final presentation requires. Independently verify safety-critical, financial, compliance, or production decisions.

Alternative or Complementary approaches

Check the result against the current datasheet and worst-case operating corners, then verify the circuit or measurement with simulation and bench testing where failure matters.

References

  1. Power over Ethernet — Wikipedia contributors

Similar or alternative tools

  • Transformer Total Loss

    Add winding copper, core iron, and other measured transformer losses in watts. This is a loss budget sum, not an efficiency estimate without input or output power.

  • Copper Loss

    Compute resistive winding or conductor loss as I²R from RMS current and resistance at the relevant operating temperature. Output is watts; AC skin and proximity effects are not included unless already reflected in the supplied resistance.

  • Transformer Copper Loss at Load

    Sum primary and secondary winding I²R losses using RMS currents and operating-temperature resistances. Additional windings and AC resistance effects are not included.

Don't forget to set a bookmark for tool.io!