Description
Crosswalk a supplied stored impedance imaginary component and a negative-imaginary plot value.
Electrochemical quantities require explicit electrode references, current sign, area definition and time basis. Geometric area differs from active-area conventions, charge differs from charge equivalents, and a logarithmic current coordinate needs a same-unit reference magnitude. Local sign changes and coordinate terms do not fit kinetics or establish a valid experiment.
Crosswalk a supplied stored impedance imaginary component and a negative-imaginary plot value.
When to use this tool
Use Impedance Imaginary Sign Crosswalk when you already have storedImaginaryOhms, storedAsNegativeImaginary and need to crosswalk a supplied stored impedance imaginary component and a negative-imaginary plot value.
How to use the tool and how it works
- Enter storedImaginaryOhms, storedAsNegativeImaginary. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read physicalImaginaryOhms, nyquistNegativeImaginaryOhms. Use the output convention below.
If storedAsNegativeImaginary negate the stored value to recover physicalImaginaryOhms; otherwise preserve it. Return its negative as nyquistNegativeImaginaryOhms.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| storedImaginaryOhms | Stored Imaginary Ohms | Required. Finite number. |
| storedAsNegativeImaginary | True means the stored number already represents -Im(Z); negate it to recover Im(Z). | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| physicalImaginaryOhms | Physical Imaginary Ohms | Required. Finite number. |
| nyquistNegativeImaginaryOhms | Nyquist Negative Imaginary Ohms | Required. Finite number. |
{
"input": {
"storedImaginaryOhms": 5,
"storedAsNegativeImaginary": true
},
"output": {
"physicalImaginaryOhms": -5,
"nyquistNegativeImaginaryOhms": 5
}
} Limitations and assumptions
- Units are ohms. No impedance is measured, frequency convention validated or equivalent circuit inferred.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Inspect calibrated instrument records, reference-electrode details, area definitions and the complete experiment before interpreting results. Use the full electrochemical model and verified operating conditions when a local current, charge, sweep or impedance-representation term cannot answer the scientific question.
References
Similar or alternative tools
- Impedance Phase Representation Sign
Apply an imaginary-axis representation sign to a supplied phase.
- Capacitive Inductive Reactance Crossover Flag
Compare supplied inductive and capacitive reactance magnitudes.