Voltage Divider Ratio Resistor Sensitivity Tool

Differentiate ideal divider output supply*bottom/(top+bottom) with respect to both resistors.

Loading tool…

Description

topDerivative = -supply*bottom/(top+bottom)²; bottomDerivative = supply*top/(top+bottom)².

An electrical sensitivity is a derivative at a stated operating point with the other parameters held fixed. Its units differ from the original voltage, current or resistance, and it approximates finite changes only within a suitable local range.

topDerivative = -supply*bottom/(top+bottom)²; bottomDerivative = supply*top/(top+bottom)².

When to use this tool

Use Voltage Divider Ratio Resistor Sensitivity when checking one supplied ideal-circuit derivative.

How to use the tool and how it works

  1. Enter top, bottom, supply. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read topDerivative, bottomDerivative. Use the output convention below.

Require nonnegative top and bottom resistances with positive sum. topDerivative = -supply*bottom/(top+bottom)²; bottomDerivative = supply*top/(top+bottom)².1

Input fieldMeaning and unitsAccepted input
topTopRequired. Finite number; minimum 0.
bottomBottomRequired. Finite number; minimum 0.
supplySupplyRequired. Finite number.
Output fieldInterpretationReturned shape
topDerivativeTop DerivativeRequired. Finite number.
bottomDerivativeBottom DerivativeRequired. Finite number.
json
{
  "input": {
    "top": 1,
    "bottom": 1,
    "supply": 4
  },
  "output": {
    "topDerivative": -1,
    "bottomDerivative": 1
  }
}

Limitations and assumptions

  • Derivatives are output volts per resistance unit for an unloaded divider. Supply is fixed; finite changes, component tolerance, loading and heating require a broader model.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use a full tolerance, nonlinear or thermal analysis when changes are large or component conditions affect the operating point.

References

  1. Calculation and input contract: electricity/voltage-divider-ratio-resistor-sensitivity — tool.io