Resistor Thevenin Load Current Sensitivity Tool

Calculate resistor thevenin load current sensitivity from explicit caller-supplied inputs.

Loading tool…

Description

derivative = -voltage/(sourceResistance+loadResistance)², the load-current derivative with respect to load resistance.

An electrical sensitivity is a derivative at a stated operating point with the other parameters held fixed. Its units differ from the original voltage, current or resistance, and it approximates finite changes only within a suitable local range.

derivative = -voltage/(sourceResistance+loadResistance)², the load-current derivative with respect to load resistance.

When to use this tool

Use Resistor Thevenin Load Current Sensitivity when checking one supplied ideal-circuit derivative.

How to use the tool and how it works

  1. Enter voltage, sourceResistance, loadResistance. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read derivative. Use the output convention below.

Require nonnegative sourceResistance and loadResistance with positive sum. derivative = -voltage/(sourceResistance+loadResistance)², the load-current derivative with respect to load resistance.1

Input fieldMeaning and unitsAccepted input
voltageVoltageRequired. Finite number.
sourceResistanceSource ResistanceRequired. Finite number; minimum 0.
loadResistanceLoad ResistanceRequired. Finite number; minimum 0.
Output fieldInterpretationReturned shape
derivativeDerivativeRequired. Finite number.
json
{
  "input": {
    "voltage": 12,
    "sourceResistance": 2,
    "loadResistance": 4
  },
  "output": {
    "derivative": -0.3333333333333333
  }
}

Limitations and assumptions

  • With volts and ohms the output is A/ohm. This holds source voltage and resistance fixed and omits dynamic or nonlinear loading.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use a full tolerance, nonlinear or thermal analysis when changes are large or component conditions affect the operating point.

References