Electricity: Shunt Burden Single Reading Error Tool

Compute ideal ammeter shunt loading of an explicit Thevenin source, including the series burden and relative current change; no instrument rating or safety claim.

Loading tool…

Description

idealCurrent = sourceVoltage/sourceResistance; loadedCurrent = sourceVoltage/(sourceResistance+shuntResistance); burdenVoltage = loadedCurrent*shuntResistance; relativeCurrentChange = -shuntResistance/(sourceResistance+shuntResistance).

A measuring instrument becomes part of the circuit and can change the quantity it is intended to observe. A resistive loading model separates the ideal value from that loaded value while leaving actual instrument behavior to calibration.

idealCurrent = sourceVoltage/sourceResistance; loadedCurrent = sourceVoltage/(sourceResistance+shuntResistance); burdenVoltage = loadedCurrent*shuntResistance; relativeCurrentChange = -shuntResistance/(sourceResistance+shuntResistance).

When to use this tool

Use Electricity: Shunt Burden Single Reading Error when checking a supplied resistive meter-loading effect.

How to use the tool and how it works

  1. Enter sourceVoltage, sourceResistance, shuntResistance. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read result. Expand result to inspect the returned fields.

Require positive sourceResistance and nonnegative shuntResistance. idealCurrent = sourceVoltage/sourceResistance; loadedCurrent = sourceVoltage/(sourceResistance+shuntResistance); burdenVoltage = loadedCurrent*shuntResistance; relativeCurrentChange = -shuntResistance/(sourceResistance+shuntResistance).1

Input fieldMeaning and unitsAccepted input
sourceVoltageSource VoltageRequired. Finite number.
sourceResistanceSource ResistanceRequired. Finite number.
shuntResistanceShunt ResistanceRequired. Finite number.
Output fieldInterpretationReturned shape
resultObject containing the named calculated members below.Required. Object.
result.idealCurrentIdeal CurrentCalculated result member: number.
result.loadedCurrentLoaded CurrentCalculated result member: number.
result.burdenVoltageBurden VoltageCalculated result member: number.
result.relativeCurrentChangeModel fractional change, defined algebraically even for zero source voltage.Calculated result member: number.
json
{
  "input": {
    "sourceVoltage": 10,
    "sourceResistance": 4,
    "shuntResistance": 1
  },
  "output": {
    "result": {
      "idealCurrent": 2.5,
      "loadedCurrent": 2,
      "burdenVoltage": 2,
      "relativeCurrentChange": -0.2
    }
  }
}

Limitations and assumptions

  • The relative change is a model factor even for zero source voltage, where the ratio of actual zero currents would be undefined. Lead resistance, heating and meter uncertainty are omitted.
  • Outputs are nested inside result. Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use the instrument specifications and a complete source model when frequency response, lead effects, accuracy or safe measurement matters.

References

  1. Calculation and input contract: electricity/shunt-burden-single-reading-error — tool.io

Similar or alternative tools