Skip to content

Main content

Electricity: Resistor Conductance Weighted Current Share Tool

Compute one parallel-resistor branch current from total current, its resistance and the independently summed other-branch conductance; ideal resistive split only.

Loading tool…

Description

branchCurrent = totalCurrent/(1+branchResistance*otherConductance).

Ideal electrical component relations assume a stated topology, fixed parameters and coherent units. A local voltage, current or transformation term can be algebraically valid without accounting for parasitics, ratings or safe practical connections.

branchCurrent = totalCurrent/(1+branchResistance*otherConductance).

When to use this tool

Use Electricity: Resistor Conductance Weighted Current Share when checking one explicit ideal-component or divider relationship.

How to use the tool and how it works

  1. Enter totalCurrent, branchResistance, otherConductance. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read result. Expand result to inspect the returned fields.

Require positive branchResistance and nonnegative otherConductance. branchCurrent = totalCurrent/(1+branchResistance*otherConductance).1

Input fieldMeaning and unitsAccepted input
totalCurrentTotal CurrentRequired. Finite number.
branchResistanceBranch ResistanceRequired. Finite number.
otherConductanceOther ConductanceRequired. Finite number.
Output fieldInterpretationReturned shape
resultObject containing the named calculated members below.Required. Object.
result.branchCurrentBranch CurrentCalculated result member: number.
json
{
  "input": {
    "totalCurrent": 6,
    "branchResistance": 2,
    "otherConductance": 1
  },
  "output": {
    "result": {
      "branchCurrent": 2
    }
  }
}

Limitations and assumptions

  • Use reciprocal resistance and conductance units so their product is dimensionless. Signed total current is preserved; branches are ideal resistors and no circuit solvability check is performed.
  • Outputs are nested inside result. Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use a complete circuit model and qualified practical design when loading, nonlinearity, transients or safety limits matter.

References

  1. Calculation and input contract: electricity/resistor-conductance-weighted-current-share — tool.io

Similar or alternative tools