Description
fraction = branchConductance/totalConductance; branchCurrent = totalCurrent*fraction.
Ideal electrical component relations assume a stated topology, fixed parameters and coherent units. A local voltage, current or transformation term can be algebraically valid without accounting for parasitics, ratings or safe practical connections.
fraction = branchConductance/totalConductance; branchCurrent = totalCurrent*fraction.
When to use this tool
Use Current Divider Conductance Fraction when checking one explicit ideal-component or divider relationship.
How to use the tool and how it works
- Enter totalCurrent, branchConductance, totalConductance. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read branchCurrent, fraction. Use the output convention below.
Require nonnegative branchConductance and positive totalConductance with branch <= total. fraction = branchConductance/totalConductance; branchCurrent = totalCurrent*fraction.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| totalCurrent | Total Current | Required. Finite number. |
| branchConductance | Branch Conductance | Required. Finite number; minimum 0. |
| totalConductance | Total Conductance | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| branchCurrent | Branch Current | Required. Finite number. |
| fraction | Dimensionless fraction on the stated denominator basis, not multiplied by 100. | Required. Finite number. |
{
"input": {
"totalCurrent": 12,
"branchConductance": 2,
"totalConductance": 6
},
"output": {
"branchCurrent": 4,
"fraction": 0.3333333333333333
}
} Limitations and assumptions
- Conductances use one unit. The total is supplied, not reconstructed from a branch list, and signed current is a reference choice rather than a detected flow direction.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use a complete circuit model and qualified practical design when loading, nonlinearity, transients or safety limits matter.
References
Similar or alternative tools
- Electricity: Resistor Conductance Weighted Current Share
branchCurrent = totalCurrent/(1+branchResistance*otherConductance).
- Delta Wye Single Impedance Branch
branch = adjacentFirst*adjacentSecond divided by that sum.