Beschlag Tragkraft Scharnier Lookup
Screen independently rated COMPLETE hinge sets against actual door mass AND width, exact installation verification separate; no adding individual hinge capacities, mass-only count lower bound or safety approval. Caller independently verifies units, applicability and matching conditions; no operational recipe, safety certification, causal efficacy or legal/resource classification is inferred.
Description
Hinge capacity applies to a matched complete set and installation condition.
Hinge capacity applies to a matched complete set and installation condition.1
A door's mass and width do not by themselves establish suitability when installation evidence is unknown. Use Beschlag Tragkraft Scharnier Lookup to evaluate the supplied inputs under the model explained below.
When to use Beschlag Tragkraft Scharnier Lookup
Use Beschlag Tragkraft Scharnier Lookup to evaluate the supplied inputs under the model explained below. Establish the units, measurement scope and model assumptions before entering values.
How to use Beschlag Tragkraft Scharnier Lookup and understand its results
- Establish the units, measurement scope and model assumptions before entering values.
- Enter Caller verified hinge set ids, Caller matched full set mass limits kg, Caller matched door width limits mm, Caller independent installation verified flags, Observed door mass kg, Observed door width mm using the field table and validation rules below, then run the tool.
- Read Compatible verified hinge set ids, Unknown installation candidate ids; interpret the units, signs, ordering and unknown-value placeholders described below.
- Correct reported input errors and rerun. Apply successful results according to their specific meanings and check the assumptions before using them in a decision.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| callerVerifiedHingeSetIds | Caller verified hinge set ids | array of string | Required; constraints below |
| callerMatchedFullSetMassLimitsKg | Caller matched full set mass limits kg | array of number | Required; constraints below |
| callerMatchedDoorWidthLimitsMm | Caller matched door width limits mm | array of number | Required; constraints below |
| callerIndependentInstallationVerifiedFlags | Caller independent installation verified flags | array of number | Required; constraints below |
| observedDoorMassKg | Observed door mass kg | number | Required; constraints below |
| observedDoorWidthMm | Observed door width mm | number | Required; constraints below |
Enter nonempty unique hinge-set IDs with aligned nonnegative complete-set mass limits in kg, door-width limits in mm and binary independently verified installation flags, plus nonnegative door mass and width. A geometric/load candidate requires mass≤limit and width≤limit. Return fitting sets with verified installation separately from fitting sets whose installation is unverified. The flag 0 is treated as unknown installation, not a witnessed failure. Limits are complete-set capacities and are not multiplied by hinge count.
fit=doorMass≤setMassLimit and doorWidth≤setWidthLimit; verified=fit and flag1; unknownInstallation=fit and flag0 Use the field order, units and branch conditions described above.
| Output field | Meaning | Value type |
|---|---|---|
| compatibleVerifiedHingeSetIds | Compatible verified hinge set ids | array |
| unknownInstallationCandidateIds | Unknown installation candidate ids | array of string |
{
"input": {
"callerVerifiedHingeSetIds": [
"a",
"b"
],
"callerMatchedFullSetMassLimitsKg": [
10,
20
],
"callerMatchedDoorWidthLimitsMm": [
100,
200
],
"callerIndependentInstallationVerifiedFlags": [
1,
0
],
"observedDoorMassKg": 15,
"observedDoorWidthMm": 150
},
"output": {
"compatibleVerifiedHingeSetIds": [],
"unknownInstallationCandidateIds": [
"b"
]
}
} Limitations and assumptions
A door's mass and width do not by themselves establish suitability when installation evidence is unknown. Apply the exact scope and assumptions explained above.
All listed fields require explicit values. Unexpected fields, incorrect types, nonfinite numbers and sparse arrays fail validation. Domain-specific bounds, alignments and supported tokens are explained above; extremely large inputs or outputs can also be rejected. Input errors differ from successful false results, empty match lists and unknown-evidence placeholders.
Alternative or Complementary methods
Use Topfband Bohrbild Calculator for a related task: A hinge-bore template is transformed from local coordinates into the door-panel frame.
Use Beschlag Tragkraft Boden Calculator for a related task: Shelf-support demand should be compared with independently verified installed capacity.
References
-
Beschlag Tragkraft Scharnier Lookup — tool.io
Similar or alternative tools
- Topfband Bohrbild Calculator
A hinge-bore template is transformed from local coordinates into the door-panel frame.
- Beschlag Tragkraft Boden Calculator
Shelf-support demand should be compared with independently verified installed capacity.