Description
Scale a blank to sample mass before normalization.
Environmental-remediation bookkeeping uses explicit water, soil, dry-mass, concentration and sampling bases. A local mass residual, censored-result bound or supplied target margin does not identify a removal mechanism, establish representativeness or determine an environmentally acceptable contaminant level.
Scale a blank to sample mass before normalization.
When to use this tool
Use Remediation Blank Basis Factor when checking the stated remediation measurement, mass/volume balance or support convention.
How to use the tool and how it works
- Enter sampleSignal, blankSignal, sampleMass, blankEquivalentMass. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read scaledBlank, correctedPerMass. Use the output convention below.
Scale a blank to sample mass before normalization. Require sampleMass/blankEquivalentMass > 0; scaledBlank = blankSignal*sampleMass/blankEquivalentMass, correctedPerMass = (sampleSignal-scaledBlank)/sampleMass.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| sampleSignal | Sample Signal | Required. Finite number. |
| blankSignal | Blank Signal | Required. Finite number. |
| sampleMass | Sample Mass | Required. Finite number; strictly above 0. |
| blankEquivalentMass | Positive mass basis represented by the blank, used to scale blankSignal to sampleMass. | Required. Finite number; strictly above 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| scaledBlank | Scaled Blank | Required. Finite number. |
| correctedPerMass | Corrected Per Mass | Required. Finite number. |
{
"input": {
"sampleSignal": 20,
"blankSignal": 2,
"sampleMass": 10,
"blankEquivalentMass": 5
},
"output": {
"scaledBlank": 4,
"correctedPerMass": 1.6
}
} Limitations and assumptions
- Signals can be signed; the blank basis and linear scaling are supplied, without analytical validation or hazard interpretation.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use verified sampling and analytical data, consistent material/unit bases and a complete transport or treatment model; involve qualified environmental professionals for practical or regulatory decisions.
References
Similar or alternative tools
- Reference Site Ratio Gap
Compare a site/reference ratio with a supplied ratio.
- Bioremediation Supplied Target Margin
Compare measurement with a supplied target and upper uncertainty.