Fluorophore Bleach Step Height

Describe a signed observed fluorescence step and its fraction of a positive background-corrected initial level without inferring fluorophore count.

Loading tool…

Description

Compare supplied before/after fluorescence levels relative to a background.

Biophysical scalar models require explicit signal, concentration, temperature, energy and geometric conventions. Effective concentration differs from dimensionless activity, a single displacement differs from mean-square displacement, and a fluorescence yield ratio needs absorption and refractive-index corrections. Supplied model parameters do not establish that the model applies to an experiment.

Compare supplied before/after fluorescence levels relative to a background.

When to use this tool

Use Fluorophore Bleach Step Height when you already have beforeLevel, afterLevel, backgroundLevel and need to compare supplied before/after fluorescence levels relative to a background.

How to use the tool and how it works

  1. Enter beforeLevel, afterLevel, backgroundLevel. Use the units and conventions below.
  2. Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
  3. Read stepHeight, backgroundCorrectedBefore, relativeStep. Use the output convention below.

Require beforeLevel>backgroundLevel; step=before-after, correctedBefore=before-background, relativeStep=step/correctedBefore.1

Input fieldMeaning and unitsAccepted input
beforeLevelBefore LevelRequired. Finite number.
afterLevelAfter LevelRequired. Finite number.
backgroundLevelBackground LevelRequired. Finite number.
Output fieldInterpretationReturned shape
stepHeightStep HeightRequired. Finite number.
backgroundCorrectedBeforeBackground Corrected BeforeRequired. Finite number.
relativeStep(beforeLevel-afterLevel)/(beforeLevel-backgroundLevel); can be negative or above one, without counting molecules.Required. Finite number.
json
{
  "input": {
    "beforeLevel": 120,
    "afterLevel": 90,
    "backgroundLevel": 20
  },
  "output": {
    "stepHeight": 30,
    "backgroundCorrectedBefore": 100,
    "relativeStep": 0.3
  }
}

Limitations and assumptions

  • After-level is unrestricted, so negative or above-one relative steps are accepted. No bleaching, fluorophore count, background or actual molecular event is inferred.
  • Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
  • Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.

Alternative or Complementary methods

Use the complete physical model, calibrated measurements and uncertainty analysis. Check reference states, photon-signal bases, diffusion assumptions and binding-constant conventions before interpreting local contributions as physical measurements.

References

  1. Calculation and input contract: biophysics/fluorophore-bleach-step-height — tool.io

Similar or alternative tools