Probiotic Serving Label Audit

Compare a serving CFU estimate with a label claim using measured concentration and caller-supplied viability retention.

Description

A per-serving viable count combines measured concentration, serving mass and a retained-viability assumption.

A per-serving viable count combines measured concentration, serving mass and a retained-viability assumption. Comparing it with a label claim assesses the declared quantity model rather than proving a product's health effects.1

Compare a serving CFU estimate with a label claim using measured concentration and caller-supplied viability retention.

When to use Probiotic Serving Label Audit

Use this tool to compare a serving CFU estimate with a label claim using measured concentration and caller-supplied viability retention.

Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.

How to use Probiotic Serving Label Audit and understand its results

  1. Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
  2. Enter measuredCfuPerGram, servingGrams, retainedViabilityFraction, labelCfuPerServing using the field table and calculation rules, then run the tool.
  3. Read estimatedCfuPerServing, labelCoverageFraction, meetsLabelClaim. The explanation below defines the units, signs, ordering and any flags or placeholder values.
  4. If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
Input fieldMeaningValue type; see rules belowRequirement
measuredCfuPerGramMeasured cfu per gramnumber; minimum: 0Required
servingGramsServing gramsnumberRequired
retainedViabilityFractionRetained viability fractionnumber; minimum: 0; maximum: 1Required
labelCfuPerServingLabel cfu per servingnumberRequired

Enter nonnegative measured CFU/g, positive serving grams and label CFU/serving, with retention in [0,1]. The tool returns the estimated count, estimated-to-label coverage ratio and an inclusive meetsLabelClaim flag. Coverage can exceed one and zero retention gives zero estimated viable count.

estimatedCFU = measuredCFUPerGram × servingGrams × retentionFraction

Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.

Output fieldMeaningValue type
estimatedCfuPerServingEstimated cfu per servingnumber
labelCoverageFractionLabel coverage fractionnumber
meetsLabelClaimMeets label claimboolean
json
{
  "input": {
    "measuredCfuPerGram": 1000000000,
    "servingGrams": 2,
    "retainedViabilityFraction": 0.8,
    "labelCfuPerServing": 1000000000
  },
  "output": {
    "estimatedCfuPerServing": 1600000000,
    "labelCoverageFraction": 1.6,
    "meetsLabelClaim": true
  }
}

Limitations and assumptions

Retention is supplied rather than derived from storage or expiry testing. Species identity, assay recovery, product variability and efficacy are not checked; this is not a legal label-compliance determination.

Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.

Alternative or Complementary methods

Use Observed Decimal Reduction Time: Estimate a measured D value from positive viable counts and exposure time under log-linear death assumptions. For a complementary task, use Water Coliform Sample Compliance: Audit water-sample coliform observations against a supplied per-sample allowance, retaining tested volumes; nondetection is not guaranteed sterility.

References

  1. Probiotic Serving Label Audit — tool.io

Similar or alternative tools

  • Observed Decimal Reduction Time

    Estimate a measured D value from positive viable counts and exposure time under log-linear death assumptions.

  • Water Coliform Sample Compliance

    Audit water-sample coliform observations against a supplied per-sample allowance, retaining tested volumes; nondetection is not guaranteed sterility.

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies