Water Coliform Sample Compliance
Audit water-sample coliform observations against a supplied per-sample allowance, retaining tested volumes; nondetection is not guaranteed sterility.
Description
Water-sample compliance is a comparison with an explicit allowance for each observed sample.
Water-sample compliance is a comparison with an explicit allowance for each observed sample. Tested volume remains important because nondetection in a small aliquot is not evidence that all water is sterile.1
Audit water-sample coliform observations against a supplied per-sample allowance, retaining tested volumes; nondetection is not guaranteed sterility.
When to use Water Coliform Sample Compliance
Use this tool to audit water-sample coliform observations against a supplied per-sample allowance, retaining tested volumes; nondetection is not guaranteed sterility.
Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
How to use Water Coliform Sample Compliance and understand its results
- Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
- Enter sampleIds, coliformCounts, testedVolumesMl, maximumAllowedCount using the field table and calculation rules, then run the tool.
- Read nonconformingSamples, totalTestedVolumeMl, allObservedSamplesConform. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| sampleIds | Sample ids | list of string | Required |
| coliformCounts | Coliform counts | list of number | Required |
| testedVolumesMl | Tested volumes ml | list of number | Required |
| maximumAllowedCount | Maximum allowed count | integer; minimum: 0 | Required |
Enter distinct sample IDs with aligned nonnegative integer counts and positive tested volumes in mL, plus a nonnegative integer count allowance. The tool returns IDs exceeding the allowance, total tested volume and a flag true when none exceed it. Equality passes. Counts are compared per sample without volume normalization.
Paired lists must be nonempty and have equal lengths.
nonconforming if observedCount > maximumAllowedCount Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| nonconformingSamples | Nonconforming samples | list of string |
| totalTestedVolumeMl | Total tested volume ml | number |
| allObservedSamplesConform | All observed samples conform | boolean |
{
"input": {
"sampleIds": [
"A",
"B"
],
"coliformCounts": [
0,
1
],
"testedVolumesMl": [
100,
100
],
"maximumAllowedCount": 0
},
"output": {
"nonconformingSamples": [
"B"
],
"totalTestedVolumeMl": 200,
"allObservedSamplesConform": false
}
} Limitations and assumptions
The caller supplies the applicable policy and sampling design. This does not identify organisms, assess representativeness, establish drinking-water safety or convert counts to a common-volume concentration.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.
Alternative or Complementary methods
Use Tube Design MPN Estimate: Fit a Poisson tube-positivity MPN by maximum likelihood using actual inoculum volumes, replacing a fixed three-tube lookup table. For a complementary task, use Food Three Class Sampling Plan: Evaluate an n/c/m/M-style three-class food plate-count plan using caller limits, not a universal food-safety determination.
References
-
Water Coliform Sample Compliance — tool.io
Similar or alternative tools
- Tube Design MPN Estimate
Fit a Poisson tube-positivity MPN by maximum likelihood using actual inoculum volumes, replacing a fixed three-tube lookup table.
- Food Three Class Sampling Plan
Evaluate an n/c/m/M-style three-class food plate-count plan using caller limits, not a universal food-safety determination.