Countable Plate Selection
Select colony-count plates within caller-specified countability limits, retaining low and excessive counts separately.
Description
Colony-count plate selection separates usable-range counts from sparse and excessive counts.
Colony-count plate selection separates usable-range counts from sparse and excessive counts. The limits depend on the supplied counting method rather than a universal countability band.1
Select colony-count plates within caller-specified countability limits, retaining low and excessive counts separately.
When to use Countable Plate Selection
Use this tool to select colony-count plates within caller-specified countability limits, retaining low and excessive counts separately.
Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
How to use Countable Plate Selection and understand its results
- Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
- Enter plateIds, colonyCounts, minimumCount, maximumCount using the field table and calculation rules, then run the tool.
- Read countablePlateIds, belowRangePlateIds, aboveRangePlateIds. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| plateIds | Plate ids | list of string | Required |
| colonyCounts | Colony counts | list of number | Required |
| minimumCount | Minimum count | integer; minimum: 0 | Required |
| maximumCount | Maximum count | integer; minimum: 0 | Required |
Enter distinct plate IDs with aligned nonnegative integer counts and ordered nonnegative integer count limits. The tool returns countable, below-range and above-range IDs, preserving input order within each group. Both endpoints are countable; the same limits apply to every supplied plate.
Paired lists must be nonempty and have equal lengths.
countable if minimum≤count≤maximum Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| countablePlateIds | Countable plate ids | list of string |
| belowRangePlateIds | Below range plate ids | list of string |
| aboveRangePlateIds | Above range plate ids | list of string |
{
"input": {
"plateIds": [
"A",
"B",
"C"
],
"colonyCounts": [
20,
100,
350
],
"minimumCount": 30,
"maximumCount": 300
},
"output": {
"countablePlateIds": [
"B"
],
"belowRangePlateIds": [
"A"
],
"aboveRangePlateIds": [
"C"
]
}
} Limitations and assumptions
This selects observations without calculating concentration or selecting a dilution scheme. Confluence, colony identity, method-specific uncertainty and assay validity are not assessed.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use Plating Adjusted Transformation Efficiency: Estimate transformants per microgram from an aliquot plate, accounting for recovery volume and plate dilution. For a complementary task, use Tube Design MPN Estimate: Fit a Poisson tube-positivity MPN by maximum likelihood using actual inoculum volumes, replacing a fixed three-tube lookup table.
References
-
Countable Plate Selection — tool.io
Similar or alternative tools
- Plating Adjusted Transformation Efficiency
Estimate transformants per microgram from an aliquot plate, accounting for recovery volume and plate dilution.
- Tube Design MPN Estimate
Fit a Poisson tube-positivity MPN by maximum likelihood using actual inoculum volumes, replacing a fixed three-tube lookup table.