Ames Revertant Background Screen
Screen replicate Ames revertant counts against background with an explicit viability criterion; not a definitive mutagenicity determination.
Description
An Ames count screen compares treated revertants with background while preserving a viability gate.
An Ames count screen compares treated revertants with background while preserving a viability gate. A large count increase without adequate viability evidence is not automatically a valid positive screen.1
Screen replicate Ames revertant counts against background with an explicit viability criterion; not a definitive mutagenicity determination.
When to use Ames Revertant Background Screen
Use this tool to screen replicate Ames revertant counts against background with an explicit viability criterion; not a definitive mutagenicity determination.
Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
How to use Ames Revertant Background Screen and understand its results
- Prepare the sample, count, growth or assay measurements requested by this tool. Confirm units, sampling periods and reporting bases; supply independently established comparison criteria where requested.
- Enter treatedRevertantCounts, controlRevertantCounts, minimumFoldIncrease, treatedViabilityFraction, minimumValidViability using the field table and calculation rules, then run the tool.
- Read meanTreatedRevertants, meanControlRevertants, backgroundFoldIncrease, assayViabilityAdequate, screenFlag. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| treatedRevertantCounts | Treated revertant counts | list of number | Required |
| controlRevertantCounts | Control revertant counts | list of number | Required |
| minimumFoldIncrease | Minimum fold increase | number | Required |
| treatedViabilityFraction | Treated viability fraction | number; minimum: 0; maximum: 1 | Required |
| minimumValidViability | Minimum valid viability | number; minimum: 0; maximum: 1 | Required |
Enter nonempty replicate lists of nonnegative integer treated/control counts with positive control mean, a positive fold threshold and viability fractions in [0,1]. The tool returns both means, their ratio, an inclusive viability flag and an inclusive fold screen gated by viability. Replicate lists need not be the same length.
foldIncrease=meanTreated/meanControl; flag=viabilityAdequate AND foldIncrease≥minimumFold Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| meanTreatedRevertants | Mean treated revertants | number |
| meanControlRevertants | Mean control revertants | number |
| backgroundFoldIncrease | Background fold increase | number |
| assayViabilityAdequate | Assay viability adequate | boolean |
| screenFlag | Screen flag | boolean |
{
"input": {
"treatedRevertantCounts": [
30,
40
],
"controlRevertantCounts": [
10,
10
],
"minimumFoldIncrease": 2,
"treatedViabilityFraction": 0.9,
"minimumValidViability": 0.8
},
"output": {
"meanTreatedRevertants": 35,
"meanControlRevertants": 10,
"backgroundFoldIncrease": 3.5,
"assayViabilityAdequate": true,
"screenFlag": true
}
} Limitations and assumptions
This does not establish definitive mutagenicity, statistical significance or a dose-response pattern. Strain, controls, metabolic activation and assay design are not assessed by the count ratio.
Numeric inputs must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Lists are limited to 100,000 entries; the rules above may require smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors. A successfully returned false flag is an evaluated outcome; its meaning is explained above.
Alternative or Complementary methods
Use Fluctuation Culture Zero Class: Summarize fluctuation-test culture dispersion and the p0 mutation-event estimate from independent culture counts; not mutation frequency per cell. For a complementary task, use Viable Nonculturable Discordance: Screen discordance between viability assay and matched culturability; this pattern alone does not prove a VBNC state.
References
-
Ames Revertant Background Screen — tool.io
Similar or alternative tools
- Fluctuation Culture Zero Class
Summarize fluctuation-test culture dispersion and the p0 mutation-event estimate from independent culture counts; not mutation frequency per cell.
- Viable Nonculturable Discordance
Screen discordance between viability assay and matched culturability; this pattern alone does not prove a VBNC state.