Description
Format a supplied acoustic-reflex presentation label.
Hearing records depend on frequency, laterality, masking status, calibration and level reference. A no-response label differs from a measured threshold, while an air-minus-bone gap requires comparable test conditions. Device charge arithmetic and scalar signal offsets do not establish hearing status or suitable care.
Format a supplied acoustic-reflex presentation label.
When to use this tool
Use Acoustic Reflex Presentation Label when you already have frequencyHz, presentationSide, stimulusLevelDb, levelReference and need to format a supplied acoustic-reflex presentation label.
How to use the tool and how it works
- Enter frequencyHz, presentationSide, stimulusLevelDb, levelReference. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read label. Use the output convention below.
Require frequencyHz>0, nonempty levelReference and side ipsilateral or contralateral; display frequency, side and stimulus level/reference.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| frequencyHz | Frequency Hz | Required. Finite number; strictly above 0. |
| presentationSide | Presentation Side | Required. Text; one of "ipsilateral", "contralateral"; maximum UTF-16 length 8192. |
| stimulusLevelDb | Stimulus Level Db | Required. Finite number. |
| levelReference | Level Reference | Required. Text; minimum UTF-16 length 1; maximum UTF-16 length 8192. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| label | Label | Required. Text; maximum UTF-16 length 8192. |
{
"input": {
"frequencyHz": 1000,
"presentationSide": "ipsilateral",
"stimulusLevelDb": 80,
"levelReference": "HL"
},
"output": {
"label": "1000 Hz; ipsilateral; 80 dB HL"
}
} Limitations and assumptions
- The tool does not select a stimulus, perform a procedure, verify a reflex, assess suitability or interpret hearing.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Review original audiograms, instrument settings, test records and the complete clinical context. Use an appropriate professional assessment for interpretation; local unit conversions and supplied labels do not choose tests, presentation levels or intervention.
References
Similar or alternative tools
- Audiogram Masked Unmasked Tag
Label a supplied frequency, ear and masking flag.
- Hearing Test No Response Marker
Format a supplied response/no-response hearing-test level marker.