Description
Relabel probe depth between supplied origins.
Soil bench and profile terms depend on geometry, reference origins, heat-capacity bases and sign conventions. A pressure, stress or strain is a limited measured/model quantity rather than a complete soil-strength, heat-transport or field-state assessment. Reference lines and physical coefficients are supplied rather than inferred.
Relabel probe depth between supplied origins.
When to use this tool
Use Moisture Probe Depth Origin Token when checking the stated soil geometry, thermal, mechanical or measurement convention.
How to use the tool and how it works
- Enter recordedDepth, sensorOrigin, referenceOrigin, positiveDown. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read referenceDepth. Use the output convention below.
Relabel probe depth between supplied origins. referenceDepth = recordedDepth+(sensorOrigin-referenceOrigin)*(positiveDown ? 1 : -1).1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| recordedDepth | Recorded Depth | Required. Finite number. |
| sensorOrigin | Sensor Origin | Required. Finite number. |
| referenceOrigin | Reference Origin | Required. Finite number. |
| positiveDown | Positive Down | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| referenceDepth | Reference Depth | Required. Finite number. |
{
"input": {
"recordedDepth": 10,
"sensorOrigin": 3,
"referenceOrigin": 1,
"positiveDown": true
},
"output": {
"referenceDepth": 12
}
} Limitations and assumptions
- The origin elevations and sign convention must be compatible; no actual installation depth, spatial calibration or moisture state is verified.
- Inputs must satisfy both the field types and the cross-field conditions above. Invalid input causes an error; a successful false flag or documented placeholder is a different result.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Numeric signed-zero results are exported as zero.
Alternative or Complementary methods
Use calibrated measurements and an appropriate complete soil/engineering model for material properties, field behavior or safe practical loading.
References
Similar or alternative tools
- Penetration Depth Step Gap
Return penetration-depth step and reference discrepancy.
- Soil Air Filled Porosity Moisture Sensitivity
Return air-filled porosity before and after a water change.