GDC Curtain Spacing Lookup
Audit actual GDC center spacing against independently measured asymmetric curtain thicknesses, retaining negative overlap; not symmetric Lyre lean projection or universal canopy architecture.
Description
Divided-canopy clearance depends on each curtain’s measured width.
Divided-canopy clearance depends on each curtain’s measured width. A signed gap preserves overlaps for review.1
Enter nonempty aligned nonnegative dimensions and nonnegative minimum gap. Return signed gaps and zero-based stations strictly below the minimum.
When to use GDC Curtain Spacing Lookup
Use GDC Curtain Spacing Lookup when you need to evaluate the supplied records under the calculation and evidence rules below. No canopy architecture recommendation, growth response or load design is provided.
Prepare the measured vineyard records, aligned lists and independently verified local limits or catalog requested. Keep units, crop stages and observation periods consistent.
How to use GDC Curtain Spacing Lookup and understand its results
- Prepare the measured vineyard records, aligned lists and independently verified local limits or catalog requested. Keep units, crop stages and observation periods consistent.
- Enter observedGdcCurtainCenterSeparationsM, observedLeftCurtainHalfWidthsM, observedRightCurtainHalfWidthsM, callerMinimumClearCurtainGapM using the field table and calculation rules, then run the tool.
- Read observedGdcClearCurtainGapsM, stationsBelowCallerClearCurtainGap. The explanation below defines the units, signs, ordering and any flags or placeholder values.
- If the tool reports an input issue, correct the values and run it again. Apply the stated assumptions when interpreting a successfully returned result.
| Input field | Meaning | Value type; see rules below | Requirement |
|---|---|---|---|
| observedGdcCurtainCenterSeparationsM | Observed gdc curtain center separations m | list of number | Required |
| observedLeftCurtainHalfWidthsM | Observed left curtain half widths m | list of number | Required |
| observedRightCurtainHalfWidthsM | Observed right curtain half widths m | list of number | Required |
| callerMinimumClearCurtainGapM | Caller minimum clear curtain gap m | number | Required |
Enter nonempty aligned nonnegative dimensions and nonnegative minimum gap. Return signed gaps and zero-based stations strictly below the minimum.
gap=centerSeparation−leftHalfWidth−rightHalfWidth Units, indexing, boundary conditions and exceptional cases are defined in the calculation rules above.
| Output field | Meaning | Value type |
|---|---|---|
| observedGdcClearCurtainGapsM | Observed gdc clear curtain gaps m | list of number |
| stationsBelowCallerClearCurtainGap | Stations below caller clear curtain gap | list of number |
{
"input": {
"observedGdcCurtainCenterSeparationsM": [
2,
1.5
],
"observedLeftCurtainHalfWidthsM": [
0.5,
0.6
],
"observedRightCurtainHalfWidthsM": [
0.5,
0.6
],
"callerMinimumClearCurtainGapM": 0.5
},
"output": {
"observedGdcClearCurtainGapsM": [
1,
0.30000000000000004
],
"stationsBelowCallerClearCurtainGap": [
1
]
}
} Limitations and assumptions
No canopy architecture recommendation, growth response or load design is provided.
Numeric inputs, where present, must be finite. Follow the calculation-specific rules for overflow, underflow and exceptional cases. Numeric lists are limited to 10,000 entries; string lists to 128 strings of at most 128 characters each. The rules above may impose smaller limits. Missing required fields, extra fields, wrong value types and violations of the calculation rules are input errors.
Alternative or Complementary methods
Use Leaf Pulling Cluster Zone Percent Calculator: Leaf removal shares differ when normalized to the cluster zone or entire canopy. Keeping both denominators visible supports consistent comparison. For a complementary task, use Catch Wire Levels Spacing Calculator: Catch-wire vertical spacing is measured between ordered levels. A chosen gap band can identify deviations from a local plan.
References
-
GDC Curtain Spacing Lookup — tool.io
Similar or alternative tools
- Leaf Pulling Cluster Zone Percent Calculator
Leaf removal shares differ when normalized to the cluster zone or entire canopy. Keeping both denominators visible supports consistent comparison.
- Catch Wire Levels Spacing Calculator
Catch-wire vertical spacing is measured between ordered levels. A chosen gap band can identify deviations from a local plan.