TCID50 to PFU Approximate Poisson Converter (0.69 factor)

Convert TCID50 units using ln(2), not an empirically universal PFU calibration; assumes an ideal single-hit Poisson endpoint assay.

Description

Convert TCID50 units using ln(2), not an empirically universal PFU calibration; assumes an ideal single-hit Poisson endpoint assay.

A single-hit Poisson model links a fifty-percent endpoint to a mean of ln(2) events. That theoretical relationship can produce a conditional TCID50-to-PFU quantity under explicit assumptions.

When to use this tool

Convert TCID50 units using ln(2), not an empirically universal PFU calibration; assumes an ideal single-hit Poisson endpoint assay.

  • Prepare the supplied tcid50Units fields for this operation.
  • Compare the complete example with the representation used by your own input before carrying the result into another step.

How to use the tool and how it works

  1. Enter tcid50Units. Use the exact text syntax, units and index conventions explained below.
  2. Run the tool. If input validation fails, correct the supplied fields before interpreting any result.
  3. Read result.conditionalPfu, result.assumption. Interpret false, null and empty lists using the distinctions below; they can be valid outputs.

Require nonnegative tcid50Units, multiply by Math.LN2 and return conditionalPfu with the ideal-single-hit-Poisson assumption.1

Input fieldMeaning and representationAccepted input
tcid50Unitstcid50 units.Finite number; zero or greater
Output fieldInterpretation
resultObject containing the named outputs below.
result.conditionalPfuThe conditional pfu value under the stated formula or text convention.
result.assumptionThe assumption value under the stated formula or text convention.
json
{
  "input": {
    "tcid50Units": 100
  },
  "output": {
    "result": {
      "conditionalPfu": 69.31471805599453,
      "assumption": "ideal-single-hit-Poisson"
    }
  }
}

Limitations and assumptions

  • This is not an empirical universal assay conversion. Cell system, endpoint definition, detection probability and preparation-specific calibration are not evaluated; it does not measure infectious titer.
  • Every declared top-level field is required and unexpected fields are rejected. Numeric inputs must be finite; ordinary text fields are bounded to 8,192 UTF-16 code units, with tighter operation-specific limits where stated.
  • Ordinary string lists have at most 128 entries of at most 128 code units each; numeric lists and matrices have separate bounded size checks. Nonfinite results and excessively large serialized outputs are rejected.
  • Indexes are zero-based and spans have an exclusive end unless explicitly stated otherwise. A valid false, null or empty-list result is distinct from malformed input.

Alternative or Complementary methods

Keep physical-particle counts, infectious assay units and observed sample proportions distinct. Use the original calibration, product instructions or validated assay method for the specific context; simple conversions and reference notes do not establish infectivity or clinical interpretation.