Description
Calculate dryEnergy=wetMass*(1-moisture)*dryEnergyPerMass and netEnergy=wetMass*((1-moisture)*dryEnergyPerMass-moisture*suppliedEvaporationPenalty).
A farm or garden budget depends on a common area, quantity, observation period, and system boundary. Recovery, exclusions, overlap, and allocation change how a share is calculated. Supplied accounting or geometry terms remain separate from measured crop performance and verified environmental outcomes.
Calculate dryEnergy=wetMass*(1-moisture)*dryEnergyPerMass and netEnergy=wetMass*((1-moisture)*dryEnergyPerMass-moisture*suppliedEvaporationPenalty).
When to use this tool
Use Farm Biomass Energy Moisturebasis Gap when you need a clearly bounded area, material, resource, energy, or allocation term for supplied garden or farm records.
How to use the tool and how it works
- Enter wetMass, moisture, dryEnergyPerMass, suppliedEvaporationPenalty. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read dryEnergy, netEnergy. Use the output convention below.
Calculate dryEnergy=wetMass*(1-moisture)*dryEnergyPerMass and netEnergy=wetMass*((1-moisture)*dryEnergyPerMass-moisture*suppliedEvaporationPenalty). Require nonnegative quantities and moisture within zero through one.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| wetMass | Wet Mass | Required. Finite number; minimum 0. |
| moisture | Wet-basis moisture fraction. | Required. Finite number; minimum 0; maximum 1. |
| dryEnergyPerMass | Dry Energy Per Mass | Required. Finite number; minimum 0. |
| suppliedEvaporationPenalty | Energy deducted per unit moisture mass. | Required. Finite number; minimum 0. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| dryEnergy | Dry Energy | Required. Finite number. |
| netEnergy | Net Energy | Required. Finite number. |
{
"input": {
"wetMass": 100,
"moisture": 0.2,
"dryEnergyPerMass": 10,
"suppliedEvaporationPenalty": 2
},
"output": {
"dryEnergy": 800,
"netEnergy": 760
}
} Limitations and assumptions
- Moisture is a wet-mass fraction and energy terms need compatible units. Net energy can be negative; fuel behavior, combustion efficiency, emissions, and safe use are not modeled.
- The field tables state structural bounds; the mechanics also specify cross-field constraints. Malformed inputs and unsupported domains cause errors. A successful false flag, empty branch value, or zero placeholder has the meaning stated above and is distinct from an input error.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Verify the system boundary, units, and source records before combining this term into a resource or environmental report. Physical design and crop-performance questions require appropriate measurements and a broader model.
References
Similar or alternative tools
- Farm Energy Boundary Term
Sum supplied energy ledger terms under explicit boundaries and signed flow conventions.
- Farm Energy Reference Gap
Convert aligned nonnegative energyInputs with positive sourceFactors, sum commonEnergy, subtract creditedExports for netEnergy, and return referenceGap=netEnergy-referenceEnergy.