Rimstone Dam Pool Volume Terraced Calculator
Actual disjoint terraced pool areas×independently measured areamean waterdepths, not maxdepth or overflowing hydraulic discharge.
Description
Terraced pool volume relates each plan area to its independently measured area-mean water depth.
Terraced pool volume relates each plan area to its independently measured area-mean water depth.1
A maximum depth or a spill discharge describes a different quantity.
When to use Rimstone Dam Pool Volume Terraced Calculator
Use this tool to obtain conditionalTerracedPoolWaterVolumeCubicMeters from the supplied records using the stated calculation. Establish the survey or observation scope, reference frame, units and independently applicable calibration or qualified plan.
How to use Rimstone Dam Pool Volume Terraced Calculator and understand its results
- Establish the survey or observation scope, reference frame, units and independently applicable calibration or qualified plan.
- Enter actualTerracedPoolPlanAreasSquareMeters, callerMeasuredMeanWaterDepthsMeters, using the field meanings and rules below, then run the tool.
- Read result.conditionalTerracedPoolWaterVolumeCubicMeters. Use the units and sign conventions below, and review any unknown records separately.
- Correct any reported input issue and run again. Before using a successful result, check the stated units, signs, reference scope and observation coverage.
| Input field | Meaning | Value type | Requirement |
|---|---|---|---|
| actualTerracedPoolPlanAreasSquareMeters | Actual terraced pool plan areas square meters | list of number | Required |
| callerMeasuredMeanWaterDepthsMeters | Caller measured mean water depths meters | list of number | Required |
Supply nonempty aligned nonnegative pool plan areas in square metres and area-mean depths in metres. Multiply each matched pair and sum for cubic metres. Pool nonoverlap, average-depth measurements and complete coverage are independently established; no overflow discharge is computed.
poolVolumeM3=Σ(areaM2_i×meanDepthMeters_i) Use the matching field units and the exact boundary, ordering and reference rules above.
| Output field | Meaning | Value type |
|---|---|---|
| result | Qualified observed calculation or explicit reference | object |
| result.conditionalTerracedPoolWaterVolumeCubicMeters | Conditional Terraced Pool Water Volume Cubic Meters | number |
{
"input": {
"actualTerracedPoolPlanAreasSquareMeters": [
2,
3
],
"callerMeasuredMeanWaterDepthsMeters": [
1,
2
]
},
"output": {
"result": {
"conditionalTerracedPoolWaterVolumeCubicMeters": 8
}
}
} Limitations and assumptions
The actual observation coverage, calibration and qualified plan determine applicability. A numerical result does not establish survey accuracy, route suitability, atmosphere conditions or equipment adequacy beyond the declared comparison.
Missing required fields, unknown fields, wrong types and violated rules return input issues. Numeric values and outputs must be finite. Lists and matrices must be dense, without missing cells. Numeric lists allow at most 10000 entries, subject to the narrower lengths and code rules above. Extremely large composite outputs are rejected.
Alternative or Complementary methods
For a related step, use Cave Volume from Cross Sections Integrator: Cross-sectional areas measured along a passage describe sampled geometry. For a complementary comparison, use Passage Cross Section Area Estimator: An ordered surveyed passage boundary can define a simple polygonal cross-section.
References
Similar or alternative tools
- Cave Volume from Cross Sections Integrator
Cross-sectional areas measured along a passage describe sampled geometry.
- Passage Cross Section Area Estimator
An ordered surveyed passage boundary can define a simple polygonal cross-section.