Event Rate Limit Acceptance Trace

Trace sliding-window rate limits over accepted events in (t−window,t]; rejected events do not consume acceptance capacity.

Description

Trace sliding-window rate limits over accepted events in (t−window,t]; rejected events do not consume acceptance capacity.

A rolling rate limit can count accepted events within a moving time window. The precise open boundary determines whether an old event still occupies capacity.

When to use this tool

Trace sliding-window rate limits over accepted events in (t−window,t]; rejected events do not consume acceptance capacity.

  • Prepare the supplied eventTimes, windowDuration, maximumAccepted fields for this operation.
  • Compare the complete example with the representation used by your own input before carrying the result into another step.

How to use the tool and how it works

  1. Enter eventTimes, windowDuration, maximumAccepted. Use the exact text syntax, units and index conventions explained below.
  2. Run the tool. If input validation fails, correct the supplied fields before interpreting any result.
  3. Read result.acceptedIndexes, result.acceptance. Interpret false, null and empty lists using the distinctions below; they can be valid outputs.

Process nondecreasing times. At time t, count previously accepted events whose times are strictly greater than t-windowDuration; accept the current event only if that count is below maximumAccepted.1

Input fieldMeaning and representationAccepted input
eventTimesevent times.List of finite numbers; bounded by the operation
windowDurationwindow duration.Finite number; greater than zero
maximumAcceptedmaximum accepted.Integer from 1 to 10000 inclusive
Output fieldInterpretation
resultObject containing the named outputs below.
result.acceptedIndexesThe accepted indexes list in the ordering and representation described above.
result.acceptanceThe acceptance list in the ordering and representation described above.
json
{
  "input": {
    "eventTimes": [
      0,
      1,
      2,
      5
    ],
    "windowDuration": 3,
    "maximumAccepted": 2
  },
  "output": {
    "result": {
      "acceptedIndexes": [
        0,
        1,
        3
      ],
      "acceptance": [
        true,
        true,
        false,
        true
      ]
    }
  }
}

Limitations and assumptions

  • The window excludes its left boundary. Rejected events consume no capacity, and equal-time events are considered in input order. This is a rolling accepted-event model rather than a token bucket.
  • Every declared top-level field is required and unexpected fields are rejected. Numeric inputs must be finite; ordinary text fields are bounded to 8,192 UTF-16 code units, with tighter operation-specific limits where stated.
  • Ordinary string lists have at most 128 entries of at most 128 code units each; numeric lists and matrices have separate bounded size checks. Nonfinite results and excessively large serialized outputs are rejected.
  • Indexes are zero-based and spans have an exclusive end unless explicitly stated otherwise. A valid false, null or empty-list result is distinct from malformed input.

Alternative or Complementary methods

Choose a sampling model before combining results. Earlier-sample hold, linear interpolation and index-only differences answer different questions; event cooldown, debounce and rolling limits also use different acceptance rules.

References

  1. Tool behavior and example: Event Rate Limit Acceptance Trace — tool.io

Similar or alternative tools

  • Event Cooldown Acceptance Trace

    Accept the first event and later events at least the caller cooldown after the last accepted event; rejected events do not restart the cooldown.

  • Event Debounce Window Filter

    Plan trailing-edge debounce emissions: retain the last event of each burst separated by strictly more than the quiet window; assumes no future events after the supplied list.

Don't forget to set a bookmark for tool.io!
Privacy | Imprint | Cookies