Description
Apply supplied calibrant potency with an explicit wet/dry basis; no potency value is looked up.
Quality records separate measured results, reference values, acceptance rules, and supporting evidence. Arithmetic consistency and record coverage can be checked against supplied criteria without establishing traceability, approving a method, or deciding product conformity.
Apply supplied calibrant potency with an explicit wet/dry basis; no potency value is looked up.
When to use this tool
Use it for calibrant potency basis factor when the required inputs and conventions are already available.
How to use the tool and how it works
- Enter weighedMass, suppliedPotencyFraction, moistureFraction, potencyOnDryBasis. Use the stated units and boundary conventions.
- Run the calculation. Correct any input error before interpreting a result.
- Read activeEquivalent. Inspect any known, defined, inclusion, or boundary flags before interpreting numeric values.
Require nonnegative weighedMass and potency and moisture fractions within zero through one. Multiply mass by potency and, only when potencyOnDryBasis is true, by one minus moistureFraction.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| weighedMass | Weighed Mass | Required. Finite number; minimum 0. |
| suppliedPotencyFraction | Supplied Potency Fraction | Required. Finite number; minimum 0; maximum 1. |
| moistureFraction | Moisture Fraction | Required. Finite number; minimum 0; maximum 1. |
| potencyOnDryBasis | Potency On Dry Basis | Required. Boolean. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| activeEquivalent | Active Equivalent | Required. Finite number. |
{
"input": {
"weighedMass": 10,
"suppliedPotencyFraction": 0.8,
"moistureFraction": 0.1,
"potencyOnDryBasis": true
},
"output": {
"activeEquivalent": 7.2
}
} Limitations and assumptions
- The moisture fraction is validated even for an as-received potency basis. This computes the supplied active-equivalent basis without measuring moisture or selecting the correct assay convention.
- The field tables describe structural bounds; the mechanics also state cross-field requirements. Malformed input shapes, disallowed keys, and invalid domains cause input errors. Results must remain finite and within the declared output contract. A successful false flag or zero placeholder is distinct from an error.
- Numeric arithmetic uses binary floating point. Exact comparisons have no hidden tolerance or decimal rounding; negative zero is exported as zero. Decimal-text integer operations retain the exactness specifically stated above.
Alternative or Complementary methods
For calibrant potency basis factor, check the source records and the supplied rule before comparing the result with another method. Use a separate evidence or method review when arithmetic consistency alone cannot establish the required conclusion.
References
Similar or alternative tools
- Reference Standard Potency Factor
Compare supplied mass-basis reference-standard potency fractions without assigning assay purity or preparation instructions.
- Assay Reference Source Gap
Calculate assay reference source gap from explicit caller-supplied inputs.