Description
Sum nonnegative cellAreas under contactMask for contactArea and under both contactMask and sourceValid for supportedContactArea, then return their difference as unsupportedContactArea.
Dental laboratory and prosthetic research records distinguish measured dimensions, reference targets, material quantities, and evidence flags. Ratios and residuals depend on those measurement conventions. An idealized bench term or metadata match is separate from fabrication quality and clinical fit or suitability.
Sum nonnegative cellAreas under contactMask for contactArea and under both contactMask and sourceValid for supportedContactArea, then return their difference as unsupportedContactArea.
When to use this tool
Use Contact Mask Support Share when you need the stated laboratory, bench, geometry, or device-record term from already supplied measurements or annotations.
How to use the tool and how it works
- Enter cellAreas, contactMask, sourceValid. Keep parallel arrays aligned. Use the units and conventions below.
- Run the tool. Correct any format, range, or cross-field input error before interpreting the output.
- Read contactArea, supportedContactArea, unsupportedContactArea. Use the output convention below.
Sum nonnegative cellAreas under contactMask for contactArea and under both contactMask and sourceValid for supportedContactArea, then return their difference as unsupportedContactArea. Require aligned arrays.1
| Input field | Meaning and units | Accepted input |
|---|---|---|
| cellAreas | Cell Areas | Required. Array of finite number; minimum 0; maximum items 256. |
| contactMask | Contact Mask | Required. Array of boolean; maximum items 256. |
| sourceValid | Source Valid | Required. Array of boolean; maximum items 256. |
| Output field | Interpretation | Returned shape |
|---|---|---|
| contactArea | Contact Area | Required. Finite number. |
| supportedContactArea | Supported Contact Area | Required. Finite number. |
| unsupportedContactArea | Unsupported Contact Area | Required. Finite number. |
{
"input": {
"cellAreas": [
2,
3,
5
],
"contactMask": [
true,
true,
false
],
"sourceValid": [
true,
false,
true
]
},
"output": {
"contactArea": 5,
"supportedContactArea": 2,
"unsupportedContactArea": 3
}
} Limitations and assumptions
- Support flags are supplied annotations. The function returns areas rather than a support fraction and does not validate contact segmentation, measurement reliability, or clinical fit.
- The field tables state structural bounds; the mechanics also specify cross-field constraints. Malformed inputs and unsupported domains cause errors. A successful false flag, empty branch value, or zero placeholder has the meaning stated above and is distinct from an input error.
- Numeric calculations use binary floating point unless exact decimal-integer arithmetic is explicitly stated. No hidden measurement tolerance or decimal rounding is added; nonfinite or out-of-contract results are rejected. Signed zero is exported as zero.
Alternative or Complementary methods
Use calibrated measurements and an appropriate complete geometric, material, or laboratory method when the task requires more than one bench term. Clinical suitability requires a separate professional assessment.
References
Similar or alternative tools
- Contact Region Area Share
Return share=contactArea/regionArea with positive region area and contact area within zero and region area.
- Occlusal Film Contact Threshold Token
Evaluate an explicit bench image-signal threshold rule without selecting a clinical contact criterion.